Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 28.07.2026. Verfasst von Cheng Long und 5 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State Grid Sichuan Electric Power Company Limited.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes an operation-index-driven intelligent generation method for distribution network simulation models, integrating model library predefinition, multi-level equivalent modeling, and multi-agent collaboration into an automated pipeline. Three agents collaborate through a unified message bus, task queue, and device model library as follows: Monitor Agent performs time-series data acquisition, national-standard threshold evaluation, and topology verification to trigger modeling tasks; Energy-flow-Model Agent uses a hierarchical model library and LLM (Large Language Model) to automatically match standardized models, parses CIM topology, and applies Thevenin/Ward/three-phase admittance matrix multi-level equivalent modeling to construct Energy Flow Network (EFN) computation graphs; Device-Model-Data Agent supplies missing impedance parameters via a public device standard library. The pipeline automatically generates 15 min granularity current-state assessment models synchronized with operating conditions. Validation on eight consecutive days of 10 kV feeder field measurements (96-time sections/day, 91 transformer areas) shows three-phase voltage mean MAPE of 2.52% and 98.9% correct trigger rate with no false activations or missed detections, achieving end-to-end automation from archive parsing to model generation.

Förderung

  • State Grid Sichuan Electric Power Company Limited

Zitieren

APA

Long, C., Zhang, H., Su, X., Gao, Y., Xie, Q., & Zheng, K. (2026). Operation-Index-Driven Evaluation of Source-Grid-Load-Storage Distribution Networks via Digital Dynamic Modeling. Processes, 14(15), 2428. https://doi.org/10.3390/pr14152428

Vancouver

Long C, Zhang H, Su X, Gao Y, Xie Q, Zheng K. Operation-Index-Driven Evaluation of Source-Grid-Load-Storage Distribution Networks via Digital Dynamic Modeling. Processes. 2026;14(15):2428. doi:10.3390/pr14152428

BibTeX
@article{Long2026,
  author = {Long, Cheng and Zhang, Hua and Su, Xueneng and Gao, Yiwen and Xie, Qian and Zheng, Kun},
  title = {Operation-Index-Driven Evaluation of Source-Grid-Load-Storage Distribution Networks via Digital Dynamic Modeling},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {15},
  pages = {2428},
  doi = {10.3390/pr14152428}
}
Kostenlos starten →