Mechanism and Simulation Analysis of Resonance De-Icing for 100 m High-Voltage Transmission Line
Processes · 15.06.2026 · 14 (12) · 1952
DOI: 10.3390/pr14121952 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 15.06.2026. Verfasst von Yu Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the foundation of Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Ministry of Education, P.R. China, Shanxi Key Laboratory of Integrated Energy System, Research and Development of Key Technologies for New Power System Sources and Storage under Extreme Conditions and Simulation Test Platform.
Abstract (Originalsprache)
To address safety hazards such as line damage and operational instability caused by icing on high-voltage overhead transmission lines, this study conducts numerical simulation research on wire vibration de-icing based on the ANSYS finite element platform. Using a 100 m span transmission line as the research model, 49.8 m ice-covered sections are set on both sides of the line, and the 0.4 m range in the middle is designated as the concentrated excitation force area of the vibration motor. By applying intermittent harmonic loads in the excitation stage, the process of mechanical vibration de-icing is accurately reproduced. At the same time, life and death element technology is introduced to remove ice-covered units with stress exceeding the critical failure threshold, accurately realizing the dynamic simulation of the entire process of ice-covering cracking and detachment. This study selects resonance frequency bands that are suitable for the structural characteristics of the transmission line through static analysis, modal analysis, and harmonic response analysis, and preliminarily locks in candidate excitation frequencies. Combined with transient dynamics simulation, the optimal excitation frequency for vibration de-icing of transmission lines is determined by comprehensively considering the efficiency of de-icing and the safety constraints of conductor dancing. A method for determining the optimal de-icing frequency based on multi-step finite element analysis has been developed, which can provide theoretical support and simulation reference for the structural design, frequency matching, and operational parameter optimization of mechanical vibration de-icing devices for high-voltage transmission lines and overhead cables.
Förderung
- the foundation of Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Ministry of Education, P.R. China
- Shanxi Key Laboratory of Integrated Energy System
- Research and Development of Key Technologies for New Power System Sources and Storage under Extreme Conditions and Simulation Test Platform
Zitieren
APA
Zhang, Y., Dou, Y., Liu, F., Zhao, L., Jiao, Y., & Li, H. (2026). Mechanism and Simulation Analysis of Resonance De-Icing for 100 m High-Voltage Transmission Line. Processes, 14(12), 1952. https://doi.org/10.3390/pr14121952
Vancouver
Zhang Y, Dou Y, Liu F, Zhao L, Jiao Y, Li H. Mechanism and Simulation Analysis of Resonance De-Icing for 100 m High-Voltage Transmission Line. Processes. 2026;14(12):1952. doi:10.3390/pr14121952
BibTeX
@article{Zhang2026,
author = {Zhang, Yu and Dou, Yinke and Liu, Fujia and Zhao, Liangliang and Jiao, Yangyang and Li, Huajian},
title = {Mechanism and Simulation Analysis of Resonance De-Icing for 100 m High-Voltage Transmission Line},
journal = {Processes},
year = {2026},
volume = {14},
number = {12},
pages = {1952},
doi = {10.3390/pr14121952}
}
EUVIMED