Mechanistic Study on the Internal Thermodynamic Response of a Liquid Hydrogen Tank Under Support Thermal Bridge-Induced Non-Uniform Heat Input
Processes · 13.06.2026 · 14 (12) · 1940
DOI: 10.3390/pr14121940 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 13.06.2026. Verfasst von Hui Lv und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Project of Anhui Provincial Department of Education.
Abstract (Originalsprache)
Support structures in liquid hydrogen tanks act as localized thermal bridges between the ambient temperature outer vessel and the cryogenic inner vessel. However, the difference between support thermal bridge-induced localized heat input and equivalent uniform heat input remains insufficiently clarified, especially regarding their effects on local thermal behavior and support position-dependent thermodynamic response. In this study, a gas–liquid two-phase CFD model was developed for a 37.4 m3 liquid hydrogen tank at a 50% filling ratio. Localized heat flux regions were used to represent support thermal bridges, and an equivalent uniform heat input case with the same total heat input was introduced for comparison. The results show that localized support heat input concentrates the high-temperature region near the support-corresponding wall area and induces stronger local natural convection with a maximum velocity of approximately 0.27 m/s, compared to approximately 0.14 m/s in the uniform heat input case. The uniform heat input case produces a slightly higher overall gas-phase pressure, but it cannot capture the local heat accumulation and flow field reconstruction caused by support thermal bridges. Circumferential support position variation mainly affects the relative position between the localized heat source, gas region, liquid region, and gas–liquid interface. Upper support position variation has a more pronounced influence on local peak temperature and flow intensity than lower support variation. Axial support position variation mainly shifts the local high-temperature and high-velocity regions along the tank length, while its influence on overall pressure response is limited. These results indicate that equivalent uniform heat input can approximate the overall pressurization trend, but localized support heat input boundaries should be retained when local temperature fields, flow structures, and support layout effects are of concern.
Förderung
- Key Project of Anhui Provincial Department of Education
Zitieren
APA
Lv, H., Ding, H., Song, J., & Hao, C. (2026). Mechanistic Study on the Internal Thermodynamic Response of a Liquid Hydrogen Tank Under Support Thermal Bridge-Induced Non-Uniform Heat Input. Processes, 14(12), 1940. https://doi.org/10.3390/pr14121940
Vancouver
Lv H, Ding H, Song J, Hao C. Mechanistic Study on the Internal Thermodynamic Response of a Liquid Hydrogen Tank Under Support Thermal Bridge-Induced Non-Uniform Heat Input. Processes. 2026;14(12):1940. doi:10.3390/pr14121940
BibTeX
@article{Lv2026,
author = {Lv, Hui and Ding, Hua and Song, Jianhao and Hao, Chaoyang},
title = {Mechanistic Study on the Internal Thermodynamic Response of a Liquid Hydrogen Tank Under Support Thermal Bridge-Induced Non-Uniform Heat Input},
journal = {Processes},
year = {2026},
volume = {14},
number = {12},
pages = {1940},
doi = {10.3390/pr14121940}
}
EUVIMED