Inversion and Dynamic Control of Local Heating Temperature Fields in Wellhead-Produced Fluids
Processes · 10.06.2026 · 14 (12) · 1891
DOI: 10.3390/pr14121891 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 10.06.2026. Verfasst von Xinwei Wang und 7 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Oil & Gas Major Project “Oil and Gas Production Systems Re-engineering Technology and Equipment”.
Abstract (Originalsprache)
During heavy oil development, the gathering and transportation of low-temperature wellhead-produced fluids are often accompanied by high viscosity, pipe-wall deposition, and high flow resistance, threatening the continuous and stable operation of gathering systems. Existing studies on wellhead heating mainly focus on overall steady-state heating performance, while variable-flow heat transfer and start–stop control in local heating systems remain insufficiently explored. This study aims to evaluate the steady-state heating capacity, transient thermal response, and start–stop control performance of a localized electric heating section under variable-flow conditions. A 3D fluid–solid-coupled heat-transfer model of the heating element, pipe wall, and internal fluid was developed using COMSOL Multiphysics. The steady-state temperature field, transient heating and cooling behavior, and start–stop control characteristics were analyzed under different flow rates. The results show that, at a heating power of 15 kW and a flow rate of 20 m3/d, the maximum outer-wall temperature reached 564 K, and the average outlet fluid temperature reached 308.83 K, indicating effective heating performance. As the flow rate increased from 10 m3/d to 30 m3/d, the maximum pipe-wall temperature and fluid temperature rise both decreased, whereas the average fluid-side heat-transfer coefficient increased from approximately 700 W/(m2·K) to 1800 W/(m2·K), demonstrating enhanced convective heat transfer. Under a dual-threshold control strategy of 463.15–483.15 K, the system maintained the target temperature near 473.15 K under all tested conditions, while the load factor increased from 37.83% to 86.15%. These findings provide theoretical references and engineering support for optimizing power configuration and improving temperature control strategies in local heating systems for wellhead-produced fluids.
Förderung
- Oil & Gas Major Project “Oil and Gas Production Systems Re-engineering Technology and Equipment”
Zitieren
APA
Wang, X., Wu, H., Sun, D., Ma, L., Zhang, P., Fan, C., Wang, H., & Lin, R. (2026). Inversion and Dynamic Control of Local Heating Temperature Fields in Wellhead-Produced Fluids. Processes, 14(12), 1891. https://doi.org/10.3390/pr14121891
Vancouver
Wang X, Wu H, Sun D, Ma L, Zhang P, Fan C, et al. Inversion and Dynamic Control of Local Heating Temperature Fields in Wellhead-Produced Fluids. Processes. 2026;14(12):1891. doi:10.3390/pr14121891
BibTeX
@article{Wang2026,
author = {Wang, Xinwei and Wu, Huiqin and Sun, Dong and Ma, Lihui and Zhang, Pan and Fan, Chenyu and Wang, Haorong and Lin, Riyi},
title = {Inversion and Dynamic Control of Local Heating Temperature Fields in Wellhead-Produced Fluids},
journal = {Processes},
year = {2026},
volume = {14},
number = {12},
pages = {1891},
doi = {10.3390/pr14121891}
}
EUVIMED