Effect of Interelectrode Distance on the Dynamic Behavior of Particulate Matter Under a Passive Air Purifier: An Experimental Study

Bao Zhang, Linling Zhu, Xiaochuan Li, Tao Wei

Processes · 16.05.2026 · 14 (10) · 1615

DOI: 10.3390/pr14101615 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 16.05.2026. Verfasst von Bao Zhang und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Interelectrode distance is a key structural parameter of passive air purifiers based on the particle sink effect, but its influence on particulate matter (PM) dynamics remains unclear. This study experimentally investigates the concentration evolution of PM in four size ranges (≤1, 1–2.5, 2.5–10, >10 μm) under different interelectrode distances in a confined space, combined with multifractal detrended fluctuation analysis (MF-DFA) and coupling detrended fluctuation analysis (CDFA). Results show a non-monotonic effect of interelectrode distance on PM removal, with an optimal range of 3–4 cm. Submicron PM (≤1 μm) exhibits a short-term rise followed by a decline; the rising phase duration increases with larger interelectrode distance, revealing a competition between fragmentation-induced release of large particles and their capture. MF-DFA indicates that concentration series of each PM size range display typical multifractal behavior, and the skewness direction of the multifractal spectrum varies with interelectrode distance and particle size. CDFA further reveals strong coupled multifractal features among concentration series of the same particle size at different distances, with coupling strength increasing with particle size. The skewness evolution of the coupled multifractal spectrum quantitatively uncovers how the interelectrode distance, through non-monotonic matching between electric field intensity and dust collection area, regulates PM concentrations toward higher or lower values. This study provides a mechanistic basis for optimizing passive air purifier structures.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, B., Zhu, L., Li, X., & Wei, T. (2026). Effect of Interelectrode Distance on the Dynamic Behavior of Particulate Matter Under a Passive Air Purifier: An Experimental Study. Processes, 14(10), 1615. https://doi.org/10.3390/pr14101615

Vancouver

Zhang B, Zhu L, Li X, Wei T. Effect of Interelectrode Distance on the Dynamic Behavior of Particulate Matter Under a Passive Air Purifier: An Experimental Study. Processes. 2026;14(10):1615. doi:10.3390/pr14101615

BibTeX
@article{Zhang2026,
  author = {Zhang, Bao and Zhu, Linling and Li, Xiaochuan and Wei, Tao},
  title = {Effect of Interelectrode Distance on the Dynamic Behavior of Particulate Matter Under a Passive Air Purifier: An Experimental Study},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {10},
  pages = {1615},
  doi = {10.3390/pr14101615}
}
Kostenlos starten →