EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study on Cement Carbonation Resistance and Reinforcement in CCUS-EOR

Yaqiong Cao, Shiming Zhou, Rengguang Liu, Qian Tao, Luo Liu

Processes · 23.04.2026 · 14 (9) · 1352

DOI: 10.3390/pr14091352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 23.04.2026. Verfasst von Yaqiong Cao und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Key Research and Development Program of Xinjiang Uygur Autonomous Region scheme, Sinopec Corporate Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To investigate the mitigation of high-pressure CO2-induced degradation of wellbore cement sheath in Carbon Capture, Utilization, and Storage–Enhanced Oil Recovery applications (CCUS-EOR), conventional Class G oil well cement and modified cement systems incorporating graphene, waterborne epoxy resin, and a composite of waterborne epoxy resin with graphene were formulated. This study presents the original comparative investigation on the long-term carbonation resistance of graphene-modified, waterborne-epoxy-modified, and their composite-modified oil well cements under 130 °C and 7 MPa CO2 partial pressure, filling the research gap of unclear synergistic effects of the two modifiers in high-temperature CCUS environments. The specimens were subjected to simulated downhole conditions, and key properties, including compressive strength and permeability, were evaluated. The underlying mechanisms were elucidated through material characterization techniques such as X-ray diffraction, X-ray computed tomography, and scanning electron microscopy. Results indicated that the waterborne epoxy resin–modified cement system exhibited superior long-term carbonation resistance, achieving a 90 d compressive strength retention rate of 84%. The graphene-modified cement showed a 90 d compressive strength retention rate of 65%, while the waterborne epoxy–graphene composite system only retained 39.7% of its compressive strength at 90 d due to negative synergistic effects. The enhanced durability of the waterborne-epoxy-modified cement is attributed to the formation of a continuous polymeric film, which acts as a protective barrier against CO2 penetration. This study provides valuable insights for the design of CO2-resistant cement systems in CCUS-EOR environments.

Förderung

  • The Key Research and Development Program of Xinjiang Uygur Autonomous Region scheme
  • Sinopec Corporate Project

Zitieren

APA

Cao, Y., Zhou, S., Liu, R., Tao, Q., & Liu, L. (2026). Study on Cement Carbonation Resistance and Reinforcement in CCUS-EOR. Processes, 14(9), 1352. https://doi.org/10.3390/pr14091352

Vancouver

Cao Y, Zhou S, Liu R, Tao Q, Liu L. Study on Cement Carbonation Resistance and Reinforcement in CCUS-EOR. Processes. 2026;14(9):1352. doi:10.3390/pr14091352

BibTeX
@article{Cao2026,
  author = {Cao, Yaqiong and Zhou, Shiming and Liu, Rengguang and Tao, Qian and Liu, Luo},
  title = {Study on Cement Carbonation Resistance and Reinforcement in CCUS-EOR},
  journal = {Processes},
  year = {2026},
  volume = {14},
  number = {9},
  pages = {1352},
  doi = {10.3390/pr14091352}
}
Kostenlos starten →