Effectiveness and Risk Assessment of Septic Tank Treatment Systems in Rural Cold Regions of China
Processes · 30.10.2024 · 12 (11) · 2385
DOI: 10.3390/pr12112385 ↗Kurz gefasst
Fachartikel in der Zeitschrift Processes, online erschienen am 30.10.2024. Verfasst von Jinghao Bian und 6 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Chinese Academy of Agricultural Sciences.
Abstract (Originalsprache)
Rural toilet reform in cold areas is the focus and difficulty of China’s toilet revolution. In this paper, by carrying out the septic tank gradient burial depth test and regular seasonal monitoring of the operation effect of rural septic tanks in cold areas, the frost protection effect and treatment effect of rural toilets in cold areas are clarified, which provide important references for the rural toilet revolution and its practical significance in cold areas of China. Based on controlled tests and correlation analysis methods, different gradient burial depths of septic tanks (40, 60, and 80 cm) and different seasonal operation effects (spring, summer, autumn, and winter) were studied to analyze the influence of factors such as burial depths and temperatures on the effectiveness of anti-freezing and treatment of septic tanks. The results found that the septic tank effluent indexes of the six cold-zone test households could not meet requirements of Class Ⅰ-B in the discharge standard of pollutants for municipal wastewater treatment plants (GB 18918-2002). (The criteria for Class I-B are as follows: COD emission limit of 60 mg/L; SS emission limit of 20 mg/L; TN emission limit of 20 mg/L; TP emission limit of 1 mg/L; NH3-N emission limit of 8 mg/L); The average removal of suspended solids (SSs), chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP), NH3-N, and NO3-N by septic tanks was 79.7%, 21.8%, 10.5%, 13.5%, 9.76%, and 2.38%, respectively; the water temperature was significantly positively correlated with SS, TN, and TP; the double-layer insulated septic tank with medium burial depth (60 cm) could operate normally in cold areas in winter. The treatment effect of septic tanks on various indicators basically shows that summer > autumn > spring > winter. Temperature is the main limiting factor affecting the treatment effect of septic tanks.
Förderung
- the Chinese Academy of Agricultural Sciences
Zitieren
APA
Bian, J., Wei, X., Chen, P., Huang, Z., Zhang, C., Yang, B., & Wang, Q. (2024). Effectiveness and Risk Assessment of Septic Tank Treatment Systems in Rural Cold Regions of China. Processes, 12(11), 2385. https://doi.org/10.3390/pr12112385
Vancouver
Bian J, Wei X, Chen P, Huang Z, Zhang C, Yang B, et al. Effectiveness and Risk Assessment of Septic Tank Treatment Systems in Rural Cold Regions of China. Processes. 2024;12(11):2385. doi:10.3390/pr12112385
BibTeX
@article{Bian2024,
author = {Bian, Jinghao and Wei, Xiaocheng and Chen, Peizhen and Huang, Zhiping and Zhang, Chunxue and Yang, Bo and Wang, Qiang},
title = {Effectiveness and Risk Assessment of Septic Tank Treatment Systems in Rural Cold Regions of China},
journal = {Processes},
year = {2024},
volume = {12},
number = {11},
pages = {2385},
doi = {10.3390/pr12112385}
}
EUVIMED