EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermodynamically Efficient, Low-Emission Gas-to-Wire for Carbon Dioxide-Rich Natural Gas: Exhaust Gas Recycle and Rankine Cycle Intensifications

Israel Bernardo S. Poblete, José Luiz de Medeiros, Ofélia de Queiroz F. Araújo

Processes · 22.03.2024 · 12 (4) · 639

DOI: 10.3390/pr12040639 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Processes, online erschienen am 22.03.2024. Verfasst von Israel Bernardo S. Poblete und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CNPq Brazil, FAPERJ Brazil.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Onshore gas-to-wire is considered for 6.5 MMSm3/d of natural gas, with 44% mol carbon dioxide coming from offshore deep-water oil and gas fields. Base-case GTW-CONV is a conventional natural gas combined cycle, with a single-pressure Rankine cycle and 100% carbon dioxide emissions. The second variant, GTW-CCS, results from GTW-CONV with the addition of post-combustion aqueous monoethanolamine carbon capture, coupled to carbon dioxide dispatch to enhance oil recovery. Despite investment and power penalties, GTW-CCS generates both environmental and economic benefits due to carbon dioxide’s monetization for enhanced oil production. The third variant, GTW-CCS-EGR, adds two intensification layers over GTW-CCS, as follows: exhaust gas recycle and a triple-pressure Rankine cycle. Exhaust gas recycle is a beneficial intensification for carbon capture, bringing a 60% flue gas reduction (reduces column’s diameters) and a more than 100% increase in flue gas carbon dioxide content (increases driving force, reducing column’s height). GTW-CONV, GTW-CCS, and GTW-CCS-EGR were analyzed on techno-economic and environment–thermodynamic grounds. GTW-CCS-EGR’s thermodynamic analysis unveils 807 MW lost work (79.8%) in the combined cycle, followed by the post-combustion capture unit with 113 MW lost work (11.2%). GTW-CCS-EGR achieved a 35.34% thermodynamic efficiency, while GTW-CONV attained a 50.5% thermodynamic efficiency and 56% greater electricity exportation. Although carbon capture and storage imposes a 35.9% energy penalty, GTW-CCS-EGR reached a superior net value of 1816 MMUSD thanks to intensification and carbon dioxide monetization, avoiding 505.8 t/h of carbon emissions (emission factor 0.084 tCO2/MWh), while GTW-CONV entails 0.642 tCO2/MWh.

Förderung

  • CNPq Brazil
  • FAPERJ Brazil

Zitieren

APA

Poblete, I. B. S., Medeiros, J. L. D., & Araújo, O. D. Q. F. (2024). Thermodynamically Efficient, Low-Emission Gas-to-Wire for Carbon Dioxide-Rich Natural Gas: Exhaust Gas Recycle and Rankine Cycle Intensifications. Processes, 12(4), 639. https://doi.org/10.3390/pr12040639

Vancouver

Poblete IBS, Medeiros JLD, Araújo ODQF. Thermodynamically Efficient, Low-Emission Gas-to-Wire for Carbon Dioxide-Rich Natural Gas: Exhaust Gas Recycle and Rankine Cycle Intensifications. Processes. 2024;12(4):639. doi:10.3390/pr12040639

BibTeX
@article{Poblete2024,
  author = {Poblete, Israel Bernardo S. and Medeiros, José Luiz de and Araújo, Ofélia de Queiroz F.},
  title = {Thermodynamically Efficient, Low-Emission Gas-to-Wire for Carbon Dioxide-Rich Natural Gas: Exhaust Gas Recycle and Rankine Cycle Intensifications},
  journal = {Processes},
  year = {2024},
  volume = {12},
  number = {4},
  pages = {639},
  doi = {10.3390/pr12040639}
}
Kostenlos starten →