Frequency-Dependent Surface-Discharge Lifetime and PRPD Failure Signatures of Polyimide Insulation Under High-Frequency Sinusoidal Voltage
Polymers · 15.08.2026 · 18 (16) · 1987
DOI: 10.3390/polym18161987 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 15.08.2026. Verfasst von Bei Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, The University of Edinburgh, Edinburgh EH9 3FB, UK. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Polyimide (PI) film is a widely used insulation material in high-frequency power equipment, yet its frequency–lifetime relation and terminal discharge features have rarely been resolved together over a complete ageing trajectory. This paper reports three contributions. First, a condition-specific frequency–lifetime relation for PI surface insulation is presented, in which the discharge inception voltage is frequency-invariant while the flashover voltage and the surface lifetime both fall with frequency. Second, a stage-resolved discharge morphology derived from phase-resolved patterns is proposed, in which a late-stage finger-like cluster serves as a candidate flashover precursor, complemented by a count-aware, time-normalised discharge activity proxy. Third, a space-charge interpretation linking the per-cycle charge injection budget growth at high frequency to the suppressed inter-cycle dissipation, jointly accounting for the lifetime relation and the non-dendritic damage morphology, is presented. The fitted lifetime relation provides a quantitative planning basis over the tested 10–40 kHz grid for insulation design of high-frequency power equipment, and the finger signature provides a candidate device-level morphological criterion for online monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Engineering, The University of Edinburgh, Edinburgh EH9 3FB, UK.
- State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China.
ORCID-Profile: Bei Li, Tianrun Qi, Qingmin Li
Zitieren
APA
Li, B., Qi, T., & Li, Q. (2026). Frequency-Dependent Surface-Discharge Lifetime and PRPD Failure Signatures of Polyimide Insulation Under High-Frequency Sinusoidal Voltage. Polymers, 18(16), 1987. https://doi.org/10.3390/polym18161987
Vancouver
Li B, Qi T, Li Q. Frequency-Dependent Surface-Discharge Lifetime and PRPD Failure Signatures of Polyimide Insulation Under High-Frequency Sinusoidal Voltage. Polymers. 2026;18(16):1987. doi:10.3390/polym18161987
BibTeX
@article{Li2026,
author = {Li, Bei and Qi, Tianrun and Li, Qingmin},
title = {Frequency-Dependent Surface-Discharge Lifetime and PRPD Failure Signatures of Polyimide Insulation Under High-Frequency Sinusoidal Voltage},
journal = {Polymers},
year = {2026},
volume = {18},
number = {16},
pages = {1987},
doi = {10.3390/polym18161987}
}
EUVIMED