EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Target-Specific Electrochemical Sensing of Pipecolic Acid via Molecular Imprinting

Nihal Ermiş iD

Polymers · 28.04.2026 · 18 (9) · 1066

DOI: 10.3390/polym18091066 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 28.04.2026. Verfasst von Nihal Ermiş. Beteiligte Einrichtung: Department of Fundamental Sciences, Faculty of Engineering and Natural Sciences, Samsun University, 55420 Samsun, Türkiye. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pipecolic acid (PA) is an important biomarker associated with peroxisomal and neurological disorders, necessitating the development of rapid, selective, and cost-effective detection methods beyond conventional chromatographic techniques. In this study, a molecularly imprinted electrochemical sensor (PA-MIP/Au) was developed for the selective determination of PA. The sensor was fabricated by electropolymerizing pyrrole on a gold electrode in the presence of PA as a template, followed by template removal to create specific recognition cavities. The electrochemical behavior and analytical performance were evaluated using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) in a ferri/ferrocyanide redox system. The sensor exhibited a linear response over 5–100 µM, with a detection limit of 1.05 µM. This range covers the reported physiological plasma concentrations of pipecolic acid (0.7–2.6 µM) and extends to elevated levels observed in pathological conditions, thereby demonstrating its suitability for clinical and biochemical monitoring applications. The sensor also demonstrated high selectivity against structurally similar amino acids, good repeatability, reproducibility, and stability, retaining over 87% of its initial response after 28 days. Recovery studies in spiked artificial plasma samples yielded values between 97.2% and 98.4%, confirming its applicability in complex matrices. Overall, the proposed sensor offers a simple, rapid, and cost-effective alternative for PA determination with potential for clinical and point-of-care applications.

Schlagwörter

Stichwörter der Autor:innen

differential pulse voltammetryelectrochemical sensormolecularly imprinted polymerpipecolic acidpolypyrrole

Autor:innen und Institutionen

  • Department of Fundamental Sciences, Faculty of Engineering and Natural Sciences, Samsun University, 55420 Samsun, Türkiye.
  • Department of Biomedical Engineering, Faculty of Engineering and Natural Sciences, Samsun University, 55420 Samsun, Türkiye.

ORCID-Profile: Nihal Ermiş

Zitieren

APA

Ermiş, N. (2026). Target-Specific Electrochemical Sensing of Pipecolic Acid via Molecular Imprinting. Polymers, 18(9), 1066. https://doi.org/10.3390/polym18091066

Vancouver

Ermiş N. Target-Specific Electrochemical Sensing of Pipecolic Acid via Molecular Imprinting. Polymers. 2026;18(9):1066. doi:10.3390/polym18091066

BibTeX
@article{Ermi2026,
  author = {Ermiş, Nihal},
  title = {Target-Specific Electrochemical Sensing of Pipecolic Acid via Molecular Imprinting},
  journal = {Polymers},
  year = {2026},
  volume = {18},
  number = {9},
  pages = {1066},
  doi = {10.3390/polym18091066}
}