Thermal Desorption Used to Characterize Volatile Organic Compounds of Recycled Plastics
Polymers · 25.03.2026 · 18 (7) · 792
DOI: 10.3390/polym18070792 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 25.03.2026. Verfasst von Sandra Czaker und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Polymeric Materials and Testing, Johannes Kepler University Linz, Altenbergerstraße 69, 4040 Linz, Austria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Research Promotion Agency, BMK (federal ministry for climate, environment, energy and innovation) and the FFG, Johannes Kepler Open Access Publishing Fund and the federal state of Upper Austria.
Abstract (Originalsprache)
About 10% of plastic products are recycled worldwide, highlighting the need for technology improvements based on deeper material understanding. In packaging, which holds the highest market share in plastics demand, odor and potential hazards remain critical barriers to high-quality recycling. Conventional characterization relies on chromatography with extensive sample preparation. A gas chromatography system equipped with thermal desorption and dual flame ionization and mass spectrometric detection (ATD-GC/FID-MS) was established to analyze recyclates directly, thereby accelerating technology adaptation and guiding follow-up analyses. For calibration and validation, liquid standards were introduced into TenaxTA-filled tubes via a packed column injector and compared to a loading rig. The injector exhibited losses for higher-molar-mass compounds and solvent-dependent signal shifts. A storage study on compounded recycled polypropylene stored under various conditions showed that samples not frozen in sealed containers should be analyzed within 30 days. Experiments with varying sample geometries demonstrated that higher surface-to-volume ratios increase volatile release and variability in results, highlighting the need for uniform shapes. Applying the method to recycled yogurt cups enables the identification and quantification of contaminants, facilitating optimization of the washing process. Overall, ATD-GC/FID-MS provides a rapid screening tool for recyclate quality control and supports the improvement of recycling technologies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Polymeric Materials and Testing, Johannes Kepler University Linz, Altenbergerstraße 69, 4040 Linz, Austria.
- LIT Factory, Johannes Kepler University Linz, Altenbergerstraße 69, 4040 Linz, Austria.
ORCID-Profile: Sandra Czaker, Joerg Fischer
Förderung
- Austrian Research Promotion Agency
- BMK (federal ministry for climate, environment, energy and innovation) and the FFG
- Johannes Kepler Open Access Publishing Fund and the federal state of Upper Austria
Zitieren
APA
Czaker, S., & Fischer, J. (2026). Thermal Desorption Used to Characterize Volatile Organic Compounds of Recycled Plastics. Polymers, 18(7), 792. https://doi.org/10.3390/polym18070792
Vancouver
Czaker S, Fischer J. Thermal Desorption Used to Characterize Volatile Organic Compounds of Recycled Plastics. Polymers. 2026;18(7):792. doi:10.3390/polym18070792
BibTeX
@article{Czaker2026,
author = {Czaker, Sandra and Fischer, Joerg},
title = {Thermal Desorption Used to Characterize Volatile Organic Compounds of Recycled Plastics},
journal = {Polymers},
year = {2026},
volume = {18},
number = {7},
pages = {792},
doi = {10.3390/polym18070792}
}
EUVIMED