Fachartikel in der Zeitschrift Polymers, online erschienen am 01.09.2025. Verfasst von Guixiang Xie und 4 weiteren Autor:innen. Beteiligte Einrichtung: Fujian Provincial Key Laboratory of Clean Energy Materials, Longyan Nonferrous Metal Industry Research Institute, College of Chemistry and Material S…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Fujian Province, Higher education laboratory scientific research Foundation of Fujian Province, Education and teaching reform research foundation of Longyan Universtiy.
Abstract (Originalsprache)
Thermogravimetric analysis (TGA) has been extensively applied in polymeric characterization and quality inspection, facilitating in-depth investigations of the microstructural thermal response characteristics of polymers, including thermal stability, composition analysis, and thermal decomposition mechanisms. Here, the impacts of six factors on the TG thermal analysis curves obtained during operation are systematically examined while analyzing their causes and recommending solutions. Furthermore, the thermal degradation kinetics of an ionomer formed by neutralizing an ethylene–methacrylic acid copolymer with metal ions (SGP membrane) used in laminated tempered glass is analyzed using the Arrhenius equation, Ozawa–Flynn–Wall hypothesis and Kissinger method. Kinetic parameters at 5% degradation are fitted and used to predict the service lifetime of the SGP membrane. The results indicate that the SGP membrane sample exhibits activation energy Ea = 136.90 kJ/mol, reaction order n = 1.65 and pre-factor A = e25.93. It can be seen that the service lifetime of the SGP membrane sample is 16 years at 80 °C and 1.65 years at 100 °C.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Fujian Provincial Key Laboratory of Clean Energy Materials, Longyan Nonferrous Metal Industry Research Institute, College of Chemistry and Material Science, Longyan University, Longyan 364012, China.
- Fujian Key Laboratory of Photoelectric Functional Materials, Huaqiao University, Xiamen 361021, China.
Förderung
- Natural Science Foundation of Fujian Province
- Higher education laboratory scientific research Foundation of Fujian Province
- Education and teaching reform research foundation of Longyan Universtiy
- the Open Research Project Foundation of Fujian Key Laboratory of Photoelectric Functional Materials
- National College Student Innovation Training Project Foundation of China
- Education and Teaching Reform Research Foundation of Longyan University
- Open Research Project Foundation of Fujian Key Laboratory of Photoelectric Functional Materials
Zitieren
APA
Xie, G., Lu, Y., Lu, X., Zhang, Z., & Lin, S. (2025). Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers. Polymers, 17(17), 2390. https://doi.org/10.3390/polym17172390
Vancouver
Xie G, Lu Y, Lu X, Zhang Z, Lin S. Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers. Polymers. 2025;17(17):2390. doi:10.3390/polym17172390
BibTeX
@article{Xie2025,
author = {Xie, Guixiang and Lu, Yaqi and Lu, Xiaochun and Zhang, Zhusen and Lin, Shuidong},
title = {Measurement Error Analysis and Thermal Degradation Kinetic Model Improvement for Thermogravimetric Analyzers},
journal = {Polymers},
year = {2025},
volume = {17},
number = {17},
pages = {2390},
doi = {10.3390/polym17172390}
}
EUVIMED