EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Study on the Calculation Method of Hansen Solubility Parameters of Fuel Cell Ionomers

Chao Meng, Shang Li, Qianyun Wu, Mengyu Li, Shenao Tian, Haolin Tang iD, Mu Pan

Polymers · 21.03.2025 · 17 (7) · 840

DOI: 10.3390/polym17070840 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 21.03.2025. Verfasst von Chao Meng und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122#, Wuhan 430070, C…. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, the Foshan Xianhu Laboratory of the Advanced Energy Science and Technology Guangdong Laboratory.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurately determining the Hansen solubility parameters (HSPs) of fuel cell ionomers is crucial for optimizing the dispersion and dispersive state of the ionomer in fuel cell catalyst inks. This directly impacts the structure and coating process of the catalyst layer in proton exchange membrane fuel cells (PEMFCs). The Hansen solubility parameters (HSPs) of the Nafion ionomer were calculated by the Hansen solubility parameter software (HSPiP), inverse gas chromatography (IGC), and group contribution methods. The applicability and accuracy of the different algorithms are discussed. It was found that the solubility parameters (SPs) measured by the HSPiP method were higher, while the SPs measured by the IGC and group contribution methods were lower. However, for the ionomer with both a hydrophobic backbone and hydrophilic side chain, the HSPiP method offered a more reasonable HSP determination method. The dual HSPs of Nafion calculated by the HSPiP method were found to be δd = 16.4 MPa1/2 (dispersion force), δp = 10.5 MPa1/2 (polar interaction), and δh = 8.9 MPa1/2 (hydrogen bonding) for the hydrophobic backbone and δd = 15.2 MPa1/2, δp = 11.7 MPa1/2, and δh = 15.9 MPa1/2 for the hydrophilic side chain. These results provide a thermodynamic basis for solvent design in fuel cell catalyst-layer fabrication.

Schlagwörter

Stichwörter der Autor:innen

Hansen solubility parameterNafioninverse gas chromatographyperfluorosulfonic acid ionomer

Autor:innen und Institutionen

  • State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Luoshi Road 122#, Wuhan 430070, China.
  • National Energy Key Laboratory for New Hydrogen-Ammonia Energy Technologies, Foshan Xianhu Laboratory, No. 1 Yangming Road, Danzao Town, Nanhai District, Foshan 528200, China.
  • Hubei Key Laboratory of Fuel Cells, Wuhan University of Technology, Wuhan 430070, China.

ORCID-Profile: Haolin Tang

Förderung

  • the National Natural Science Foundation of China
  • the Foshan Xianhu Laboratory of the Advanced Energy Science and Technology Guangdong Laboratory

Zitieren

APA

Meng, C., Li, S., Wu, Q., Li, M., Tian, S., Tang, H., & Pan, M. (2025). Study on the Calculation Method of Hansen Solubility Parameters of Fuel Cell Ionomers. Polymers, 17(7), 840. https://doi.org/10.3390/polym17070840

Vancouver

Meng C, Li S, Wu Q, Li M, Tian S, Tang H, et al. Study on the Calculation Method of Hansen Solubility Parameters of Fuel Cell Ionomers. Polymers. 2025;17(7):840. doi:10.3390/polym17070840

BibTeX
@article{Meng2025,
  author = {Meng, Chao and Li, Shang and Wu, Qianyun and Li, Mengyu and Tian, Shenao and Tang, Haolin and Pan, Mu},
  title = {Study on the Calculation Method of Hansen Solubility Parameters of Fuel Cell Ionomers},
  journal = {Polymers},
  year = {2025},
  volume = {17},
  number = {7},
  pages = {840},
  doi = {10.3390/polym17070840}
}
Kostenlos starten →