EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation

Jie Yang, Ruizhe Li, Leiyu Hu, Weiwang Wang iD

Polymers · 05.06.2024 · 16 (11) · 1600

DOI: 10.3390/polym16111600 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers, online erschienen am 05.06.2024. Verfasst von Jie Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Engineering Training Center of CAVTC, Chengdu Aeronautic Polytechnic, Chengdu 610100, China. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aging of cable insulation presents a significant threat to the safe operation of cables, with space charge serving as a crucial factor influencing cable insulation degradation. However, the characteristics related to space charge and conduction current behavior during thermal aging remain unclear. This study focused on the thermal aging of cross-linked polyethylene (XLPE) material and utilizes a combined pulse electro-acoustic (PEA) and conduction current testing system to analyze the space charge and conduction current characteristics in the sample under varying electric fields and temperatures. The average charge density, short-circuit residual electric field, electric field distortion rate, and conduction current were studied. The findings indicate that the space charge in the samples following thermal aging is predominantly governed by the injected charge. The amorphous region of XLPE decreases, while the cross-linking degree increases after aging, thereby facilitating charge carrier migration within the sample and reducing the generation of charge carriers through thermal pyrolysis. The minimum temperature required for charge injection is reduced by thermal aging. Furthermore, modifications in conduction current, residual electric field, and average charge density indicate that thermal aging has the potential to alter the microstructure and trap characteristics of XLPE. This study provides empirical evidence to elucidate the underlying mechanism of cable insulation aging.

Schlagwörter

Stichwörter der Autor:innen

conductioncross-linked polyethylenespace chargethermal ageing

Autor:innen und Institutionen

  • Engineering Training Center of CAVTC, Chengdu Aeronautic Polytechnic, Chengdu 610100, China.
  • State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.

ORCID-Profile: Weiwang Wang

Zitieren

APA

Yang, J., Li, R., Hu, L., & Wang, W. (2024). Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation. Polymers, 16(11), 1600. https://doi.org/10.3390/polym16111600

Vancouver

Yang J, Li R, Hu L, Wang W. Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation. Polymers. 2024;16(11):1600. doi:10.3390/polym16111600

BibTeX
@article{Yang2024,
  author = {Yang, Jie and Li, Ruizhe and Hu, Leiyu and Wang, Weiwang},
  title = {Influence of Thermal Aging on Space Charge Characteristics and Electrical Conduction Behavior of Cross-Linked Polyethylene Cable Insulation},
  journal = {Polymers},
  year = {2024},
  volume = {16},
  number = {11},
  pages = {1600},
  doi = {10.3390/polym16111600}
}