Updates on Biomaterials Used in Total Hip Arthroplasty (THA)
Polymers · 02.08.2023 · 15 (15) · 3278
DOI: 10.3390/polym15153278 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Polymers, online erschienen am 02.08.2023. Verfasst von Liliana Savin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 190 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
One of the most popular and effective orthopedic surgical interventions for treating a variety of hip diseases is total hip arthroplasty. Despite being a radical procedure that involves replacing bone and cartilaginous surfaces with biomaterials, it produces excellent outcomes that significantly increase the patient’s quality of life. Patient factors and surgical technique, as well as biomaterials, play a role in prosthetic survival, with aseptic loosening (one of the most common causes of total hip arthroplasty failure) being linked to the quality of biomaterials utilized. Over the years, various biomaterials have been developed to limit the amount of wear particles generated over time by friction between the prosthetic head (metal alloys or ceramic) and the insert fixed in the acetabular component (polyethylene or ceramic). An ideal biomaterial must be biocompatible, have a low coefficient of friction, be corrosion resistant, and have great mechanical power. Comprehensive knowledge regarding what causes hip arthroplasty failure, as well as improvements in biomaterial quality and surgical technique, will influence the survivability of the prosthetic implant. The purpose of this article was to assess the benefits and drawbacks of various biomaterial and friction couples used in total hip arthroplasties by reviewing the scientific literature published over the last 10 years.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Faculty of Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.
- Department of Orthopedics, Clinical Rehabilitation Hospital, 700661 Iasi, Romania.
- Department of Protheses Technology, Faculty of Dental Medicine, "Grigore T. Popa" University of Medicine and Pharmacy, 700115 Iasi, Romania.
- Department of Rehabilitation, Clinical Rehabilitation Hospital, 700661 Iasi, Romania.
ORCID-Profile: Tudor Pinteala, Bogdan Veliceasa, Paul Dan Sirbu, Norin Forna
Zitieren
APA
Savin, L., Pinteala, T., Mihai, D. N., Mihailescu, D., Miu, S. S., Sirbu, M. T., Veliceasa, B., Popescu, D. C., Sirbu, P. D., & Forna, N. (2023). Updates on Biomaterials Used in Total Hip Arthroplasty (THA). Polymers, 15(15), 3278. https://doi.org/10.3390/polym15153278
Vancouver
Savin L, Pinteala T, Mihai DN, Mihailescu D, Miu SS, Sirbu MT, et al. Updates on Biomaterials Used in Total Hip Arthroplasty (THA). Polymers. 2023;15(15):3278. doi:10.3390/polym15153278
BibTeX
@article{Savin2023,
author = {Savin, Liliana and Pinteala, Tudor and Mihai, Dana Nicoleta and Mihailescu, Dan and Miu, Smaranda Stefana and Sirbu, Mihnea Theodor and Veliceasa, Bogdan and Popescu, Dragos Cristian and Sirbu, Paul Dan and Forna, Norin},
title = {Updates on Biomaterials Used in Total Hip Arthroplasty (THA)},
journal = {Polymers},
year = {2023},
volume = {15},
number = {15},
pages = {3278},
doi = {10.3390/polym15153278}
}
EUVIMED