Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM)
Plasma · 28.10.2026 · 9 (4) · 45
DOI: 10.3390/plasma9040045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Plasma, online erschienen am 28.10.2026. Verfasst von Alexsandr Gulkin und 14 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: scientific and technical program “Scientific and Technical Support of Experimental Research on the Kazakhstani Material Science Tokamak KTM”, Agency of the Republic of Kazakhstan for Atomic Energy, Ministry of Science and Higher Education of the Russian Federation.
Abstract (Originalsprache)
In the Kazakhstan Material Testing Tokamak (KTM), additional plasma heating will be achieved by injecting power in the ion cyclotron resonance frequency range using four identical generators, each delivering 2 MW of output power. Prior to transitioning the KTM into regular operation, it is necessary to tune these generators using a load equivalent that simulates plasma-like operating conditions. This article presents the electrodynamic design and analysis of a load equivalent capable of absorbing up to 2 MW of high-frequency power. The geometry and key parameters of the load equivalent for the additional high-frequency (HF) plasma heating system of the KTM tokamak are defined. The calculations are based on the assumption that the optimal solution is to construct the load equivalent as a resonator containing a saline aqueous solution absorber housed in a tank with a dielectric window. A dielectric material with high permittivity is proposed for use in the resonator structure. The results demonstrate that the developed load equivalent enables effective testing and tuning of the high-power generators, thus ensuring the readiness of the additional power injection system for scheduled activation on the KTM tokamak. Two plasma load equivalent (PLE) configurations were investigated for different bench-testing purposes. The large PLE was optimized for high RF power absorption in the standing-wave regime, whereas the small PLE was designed to provide a low-impedance loading condition for antenna-matching tests in preparation for plasma operation.
Förderung
- scientific and technical program “Scientific and Technical Support of Experimental Research on the Kazakhstani Material Science Tokamak KTM”
- Agency of the Republic of Kazakhstan for Atomic Energy
- Ministry of Science and Higher Education of the Russian Federation
Zitieren
APA
Gulkin, A., Chektybayev, B., Kusainov, A., Zhenis, K., Olkhovik, D., Zarva, D., Kotov, S., Mukeneva, S., Kashikbayev, Y., Bekmuldin, M., Mukhamedov, N., Mareev, A., Dyachenko, V., Minaev, V., & Solokha, V. (2026). Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM). Plasma, 9(4), 45. https://doi.org/10.3390/plasma9040045
Vancouver
Gulkin A, Chektybayev B, Kusainov A, Zhenis K, Olkhovik D, Zarva D, et al. Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM). Plasma. 2026;9(4):45. doi:10.3390/plasma9040045
BibTeX
@article{Gulkin2026,
author = {Gulkin, Alexsandr and Chektybayev, Baurzhan and Kusainov, Anuar and Zhenis, Kulan and Olkhovik, Dmitriy and Zarva, Denis and Kotov, Sergey and Mukeneva, Saule and Kashikbayev, Yerzhan and Bekmuldin, Maxat and Mukhamedov, Nurzhan and Mareev, Andrey and Dyachenko, Valeriy and Minaev, Vladimir and Solokha, Vladimir},
title = {Simulation of a Plasma Load Equivalent for Testing the Ion Cyclotron Resonance Heating System of the Kazakhstan Material Testing Tokamak (KTM)},
journal = {Plasma},
year = {2026},
volume = {9},
number = {4},
pages = {45},
doi = {10.3390/plasma9040045}
}
EUVIMED