Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar

Mahmood Nasser, Layla Nasser, Fatima Makhlooq, Batool Abulwahab, Elias Naser

Plasma · 31.03.2026 · 9 (2) · 10

DOI: 10.3390/plasma9020010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Plasma, online erschienen am 31.03.2026. Verfasst von Mahmood Nasser und 4 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A spatially resolved investigation of bacterial inactivation using a radiofrequency (13.56 MHz) capacitively coupled plasma (RF CCP) discharge operating in ambient air at 4.0 mbar is presented. The plasma was generated in a parallel-plate reactor without external gas precursors and characterized using Langmuir probe diagnostics and optical emission spectroscopy (OES). Electron densities on the order of 109 cm3 were measured near the powered electrode, exhibiting pronounced axial and radial gradients across the discharge volume. OES revealed strong excitation of oxygen- and nitrogen-containing emitters, including O I (777 nm), N2 s positive system (337–380 nm), and N2+ first negative system features, with emission intensities increasing monotonically with applied RF power. The bactericidal performance was evaluated using Escherichia coli American Type Culture Collection (ATCC) 11775 exposed at different axial and radial positions within the reactor. At a fixed exposure time of 60 s, the log10 reduction increased nonlinearly with RF power, rising from 0.29 at 20 W to 0.81 at 40 W, followed by a sharp transition to the assay reporting ceiling (≥2.95-log10 under the adopted half-count correction) at 50 W and above. Time-resolved measurements at 50 W demonstrated rapid inactivation kinetics, with measurable reductions occurring within 5–10 s and reaching the reporting ceiling within 60 s. In contrast, samples positioned at the chamber periphery or approximately 20 cm from the discharge center exhibited negligible inactivation, confirming strong spatial localization of the biocidal effect. These results identify a threshold-like operating regime in which increased discharge intensity produces rapid inactivation in the plasma core while remaining strongly position dependent. The findings establish medium pressure, air-based RF CCP as an efficient, gas-free, and spatially controllable platform for localized surface decontamination under non-thermal conditions.

Zitieren

APA

Nasser, M., Nasser, L., Makhlooq, F., Abulwahab, B., & Naser, E. (2026). Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar. Plasma, 9(2), 10. https://doi.org/10.3390/plasma9020010

Vancouver

Nasser M, Nasser L, Makhlooq F, Abulwahab B, Naser E. Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar. Plasma. 2026;9(2):10. doi:10.3390/plasma9020010

BibTeX
@article{Nasser2026,
  author = {Nasser, Mahmood and Nasser, Layla and Makhlooq, Fatima and Abulwahab, Batool and Naser, Elias},
  title = {Spatially Resolved Inactivation of Escherichia coli in a RF (13.56 MHz) Capacitively Coupled Air Plasma at 4.0 mbar},
  journal = {Plasma},
  year = {2026},
  volume = {9},
  number = {2},
  pages = {10},
  doi = {10.3390/plasma9020010}
}
Kostenlos starten →