EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Agreement Between Same-Day and Separate-Day Assessment of Critical Power, W′, and Peak Oxygen Uptake in Recreational Cyclists and Triathletes

Caleb S. Clay, Noah J. Perez, Payton E. Miller, John W. Farrell

Physiologia · 16.06.2026 · 6 (2) · 43

DOI: 10.3390/physiologia6020043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiologia, online erschienen am 16.06.2026. Verfasst von Caleb S. Clay und 3 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The purpose of this exploratory study was to examine mean differences, reliability, and agreement between CP and W′ derived from a 3MAT performed after an ICT and values obtained during a standalone 3MAT performed on a separate day.

Methods

Ten recreationally trained cyclists and triathletes completed four laboratory visits, including an ICT followed by a 3MAT after 30 min of recovery (same-day condition) and a standalone 3MAT performed on a separate day. CP and W′ were derived from both conditions and compared using paired t-tests and Bland–Altman agreement methods.

Results

No systematic differences, but limited individual-level agreement were observed between same-day and separate-day conditions for CP (mean difference: 1.72 ± 36.5 W) or W′ (mean difference: 0.99 ± 5.9 kJ), with trivial to small effect sizes. Peak VO2 values were also not significantly different across testing conditions (p = 0.483). However, Bland–Altman analysis revealed wide limits of agreement for both CP (−69.8 to 73.3 W) and W′ (−10.7 to 12.7 kJ), indicating substantial variability at the individual level.

Conclusions

Although same-day testing does not introduce systematic bias in CP or W′ estimation, the wide limits of agreement suggest that these protocols are not interchangeable for individual monitoring. Same-day testing may be appropriate for group-level assessments but should be used with caution when applied to individual athlete monitoring.

Zitieren

APA

Clay, C. S., Perez, N. J., Miller, P. E., & Farrell, J. W. (2026). Agreement Between Same-Day and Separate-Day Assessment of Critical Power, W′, and Peak Oxygen Uptake in Recreational Cyclists and Triathletes. Physiologia, 6(2), 43. https://doi.org/10.3390/physiologia6020043

Vancouver

Clay CS, Perez NJ, Miller PE, Farrell JW. Agreement Between Same-Day and Separate-Day Assessment of Critical Power, W′, and Peak Oxygen Uptake in Recreational Cyclists and Triathletes. Physiologia. 2026;6(2):43. doi:10.3390/physiologia6020043

BibTeX
@article{Clay2026,
  author = {Clay, Caleb S. and Perez, Noah J. and Miller, Payton E. and Farrell, John W.},
  title = {Agreement Between Same-Day and Separate-Day Assessment of Critical Power, W′, and Peak Oxygen Uptake in Recreational Cyclists and Triathletes},
  journal = {Physiologia},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {43},
  doi = {10.3390/physiologia6020043}
}
Kostenlos starten →