Reliability of the 15-s Maximal Lactate Accumulation Rate (VLamax) Test for Cycling
Physiologia · 01.11.2023 · 3 (4) · 542-551
DOI: 10.3390/physiologia3040040 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physiologia, online erschienen am 01.11.2023. Verfasst von Christopher R. Harnish und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The purpose of this study is to ascertain the reliability of two 15-s sprint cycling tests in men and women to estimate the maximum lactate accumulation rate (VLamax).
Methods
Eighteen men and twelve women completed two sprint sessions over 1 week. A 10 min warm-up preceded the obtaining of a 3 µL blood lactate (BLC) sample, after which a 15 s sprint was completed; cyclists then rested passively while multiple lactate samples were taken until the levels peaked. Trial differences and reliability across trials were analyzed using a paired-sample t-test, Pearson’s correlation, Intraclass correlation (ICC), and Bland–Altman analysis with α = 0.05 for all tests; data are reported as mean ± sd.
Results
Power (W) was similar across trials (773.0 ± 143.5 vs. 758.2 ± 127.4; p = 0.333) and the coefficient of variation (CV) of 4.7%. VLamax (mM·L−1·s−1) was similar (0.673 ± 0.024 vs. 0.635 ± 0.237; p = 0.280), but only moderately reliable across trials with CV, ICC, and R values of 18.6%, 0.661, and 0.67, respectively. Pre-BLC and peak BLC CV were 45.6 and 23.3%, respectively.
Conclusions
A 15 s VLamax cycling sprint is moderately reliable, possibly affected both by the lactate measurement and other variables used in the calculation. More research may offer ways to improve reliability.
Zitieren
APA
Harnish, C. R., Swensen, T. C., & King, D. (2023). Reliability of the 15-s Maximal Lactate Accumulation Rate (VLamax) Test for Cycling. Physiologia, 3(4), 542-551. https://doi.org/10.3390/physiologia3040040
Vancouver
Harnish CR, Swensen TC, King D. Reliability of the 15-s Maximal Lactate Accumulation Rate (VLamax) Test for Cycling. Physiologia. 2023;3(4):542-551. doi:10.3390/physiologia3040040
BibTeX
@article{Harnish2023,
author = {Harnish, Christopher R. and Swensen, Thomas C. and King, Deborah},
title = {Reliability of the 15-s Maximal Lactate Accumulation Rate (VLamax) Test for Cycling},
journal = {Physiologia},
year = {2023},
volume = {3},
number = {4},
pages = {542--551},
doi = {10.3390/physiologia3040040}
}
EUVIMED