We propose a novel silicon-based THz Mach–Zehnder interferometer (MZI) biosensor integrated with a polarization splitter and rotator (PSR). An optimized PSR is positioned at the input of the MZI, enabling arbitrary polarization inputs to be converted into the same TE mode, which eliminates the dependence of conventional MZI sensors on the input light polarization. The PSR structural parameters are optimized using 3D-FDTD simulations to achieve phase matching, and the calculation results show that efficient TM–TE-polarization conversion occurs along a coupling length of 22.9 mm. Furthermore, the PSR achieves a maximum TE-mode extinction ratio of −30.1 dB and a polarization conversion efficiency of 82.33% in the 0.44 to 0.45 THz range, effectively maintaining the polarization consistency of light entering the MZI. Meanwhile, the characteristic frequency shows a regular blue shift with increasing external refractive index, and the final results demonstrate that the designed MZI biosensor achieves a high sensitivity of 13,215.81 nm/RIU near the center frequency of 0.45 THz. All results presented in this work are obtained through numerical simulations, and experimental validation as well as analyte-concentration-dependent refractive index characterization will be addressed in future studies. To sum up, we propose a high-sensitivity terahertz MZI biosensor featuring a PSR with an on-chip integration scheme, which supports arbitrary polarization inputs and offers a highly integrated solution for specific detection in biomedicine.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yan, Z., Lu, Y., Peng, Q., Zhai, T., & Ding, G. (2026). On-Chip THz Mach–Zehnder Interferometer Integrated with Polarization Splitter and Rotator for Biomedical Applications. Photonics, 13(7), 634. https://doi.org/10.3390/photonics13070634

Vancouver

Yan Z, Lu Y, Peng Q, Zhai T, Ding G. On-Chip THz Mach–Zehnder Interferometer Integrated with Polarization Splitter and Rotator for Biomedical Applications. Photonics. 2026;13(7):634. doi:10.3390/photonics13070634

BibTeX
@article{Yan2026,
  author = {Yan, Zhehao and Lu, Yipeng and Peng, Qunzhen and Zhai, Tong and Ding, Guocheng},
  title = {On-Chip THz Mach–Zehnder Interferometer Integrated with Polarization Splitter and Rotator for Biomedical Applications},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {7},
  pages = {634},
  doi = {10.3390/photonics13070634}
}
Kostenlos starten →