EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

PPB-Level Detection of Dissolved Acetylene in Transformer Oil Based on a Clamp-Type Quartz-Enhanced Photoacoustic Spectroscopy System

Yihua Qian, Yaohong Zhao, Qing Wang, Kun Jia, Guobin Zhong, Huadan Zheng

Photonics · 01.06.2026 · 13 (6) · 545

DOI: 10.3390/photonics13060545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 01.06.2026. Verfasst von Yihua Qian und 5 weiteren Autor:innen. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: China Southern Power Grid Co., Ltd. Science and Technology Project Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dissolved gas analysis (DGA) is an essential technique for the fault diagnosis and condition monitoring of oil-immersed power transformers. Among various characteristic gases, acetylene (C2H2) is a key indicator of high-energy discharge and arc faults. In this work, a high-sensitivity dissolved acetylene detection system is developed based on clamp-type quartz-enhanced photoacoustic spectroscopy (QEPAS). A specially designed clamp-type quartz tuning fork (Clamp-type QTF) is employed as the acoustic transducer to improve acoustic coupling efficiency and optical alignment tolerance. Compared with conventional standard quartz tuning forks, the clamp-type structure exhibits enlarged acoustic interaction volume, lower damping loss, and higher signal collection capability. A near-infrared distributed feedback (DFB) laser operating at 1531.6 nm is used as the excitation source. The dissolved gas is extracted from transformer oil using a headspace degassing module and introduced into the QEPAS cell for real-time measurement. Experimental results showed that the developed system achieves a 1σ-based SNR-estimated detection limit of 17 ppb at a 50 s integration time, derived from the continuous measurement of 0.75 ppm C2H2, with excellent linearity in the concentration range from 100 ppm to 500 ppm. The measured concentration of dissolved acetylene in transformer oil is in good agreement with gas chromatography (GC), validating the effectiveness and practical applicability of the proposed system.

Förderung

  • China Southern Power Grid Co., Ltd. Science and Technology Project Fund

Zitieren

APA

Qian, Y., Zhao, Y., Wang, Q., Jia, K., Zhong, G., & Zheng, H. (2026). PPB-Level Detection of Dissolved Acetylene in Transformer Oil Based on a Clamp-Type Quartz-Enhanced Photoacoustic Spectroscopy System. Photonics, 13(6), 545. https://doi.org/10.3390/photonics13060545

Vancouver

Qian Y, Zhao Y, Wang Q, Jia K, Zhong G, Zheng H. PPB-Level Detection of Dissolved Acetylene in Transformer Oil Based on a Clamp-Type Quartz-Enhanced Photoacoustic Spectroscopy System. Photonics. 2026;13(6):545. doi:10.3390/photonics13060545

BibTeX
@article{Qian2026,
  author = {Qian, Yihua and Zhao, Yaohong and Wang, Qing and Jia, Kun and Zhong, Guobin and Zheng, Huadan},
  title = {PPB-Level Detection of Dissolved Acetylene in Transformer Oil Based on a Clamp-Type Quartz-Enhanced Photoacoustic Spectroscopy System},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {6},
  pages = {545},
  doi = {10.3390/photonics13060545}
}
Kostenlos starten →