EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution

Wenzhao Huang, Zifu Su, Weiqian Zhao, Yafei Yu, Jindong Wang, Zhengjun Wei

Photonics · 30.03.2026 · 13 (4) · 336

DOI: 10.3390/photonics13040336 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 30.03.2026. Verfasst von Wenzhao Huang und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovation Program for Quantum Science and Technology, National Natural Science Foundation of China https://ror.org/01h0zpd94, Natural Science Foundation of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Weak measurement enables the amplification of weak physical effects via post-selection and has become an important tool in precision optical metrology; however, conventional schemes based on mean-pointer shifts suffer from response saturation, limited linear range, and stringent stability requirements. Here, we propose and experimentally demonstrate a weak-measurement scheme based on spectral-interference trough shifts, where the zero-intensity points of the post-selected spectrum act as the measurement pointer, establishing an analytical mapping between the trough displacement and the target phase or time delay. Theoretical analysis shows that, under detector resolution limits, the measurement resolution depends solely on the frequency of extinction point and is independent of weak-value singular amplification or bias-phase modulation, thereby maintaining high sensitivity while avoiding pointer saturation. Experiments demonstrate that the trough-shift scheme achieves significantly better agreement between measured and theoretical sensitivities than biased weak measurement and provides a stable linear response without additional bias-compensation structures, reaching a minimum resolvable phase variation at the 10−7 level. Moreover, the approach intrinsically supports multi-period traceable measurements and exhibits strong robustness against intensity fluctuations and spectral distortions, offering a promising route toward high-sensitivity, large-dynamic-range, and stable weak measurement-based optical sensing.

Förderung

  • Innovation Program for Quantum Science and Technology
  • National Natural Science Foundation of China https://ror.org/01h0zpd94
  • Natural Science Foundation of Guangdong Province
  • Guangdong Provincial Quantum Science Strategic Initiative
  • Guangdong Provincial Key Laboratory https://ror.org/00swtqp09

Zitieren

APA

Huang, W., Su, Z., Zhao, W., Yu, Y., Wang, J., & Wei, Z. (2026). Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution. Photonics, 13(4), 336. https://doi.org/10.3390/photonics13040336

Vancouver

Huang W, Su Z, Zhao W, Yu Y, Wang J, Wei Z. Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution. Photonics. 2026;13(4):336. doi:10.3390/photonics13040336

BibTeX
@article{Huang2026,
  author = {Huang, Wenzhao and Su, Zifu and Zhao, Weiqian and Yu, Yafei and Wang, Jindong and Wei, Zhengjun},
  title = {Trough-Shift Pointer for Weak Measurement with Large Range and High Spectral Resolution},
  journal = {Photonics},
  year = {2026},
  volume = {13},
  number = {4},
  pages = {336},
  doi = {10.3390/photonics13040336}
}
Kostenlos starten →