EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-Flux Fast Photon-Counting 3D Imaging Based on Empirical Depth Error Correction

Xiaofang Wang, Tongyi Zhang, Yan Kang, Weiwei Li, Jintao Liang

Photonics · 25.11.2023 · 10 (12) · 1304

DOI: 10.3390/photonics10121304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 25.11.2023. Verfasst von Xiaofang Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Research and Development Projects of Shaanxi Province, Youth Talents Promotion Program of Xi’an.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The time-correlated single-photon-counting (TCSPC) three-dimensional (3D) imaging lidar system has broad application prospects in the field of low-light 3D imaging because of its single-photon detection sensitivity and picoseconds temporal resolution. However, conventional TCSPC systems always limit the echo photon flux to an ultra-low level to obtain high-accuracy depth images, thus needing to spend amounts of acquisition time to accumulate sufficient photon detection events to form a reliable histogram. When the echo photon flux is increased to medium or even high, the data acquisition time can be shortened, but the photon pile-up effect can seriously distort the photon histogram and cause depth errors. To realize high accuracy TCSPC depth imaging with a shorter acquisition time, we propose a high-flux fast photon-counting 3D imaging method based on empirical depth error correction. First, we derive the photon flux estimation formula and calculate the depth error of our photon-counting lidar under different photon fluxes with experimental data. Then, a function correction model between the depth errors and the number of echo photons is established by numerical fitting. Finally, the function correction model is used to correct depth images at high photon flux with different acquisition times. Experimental results show that the empirical error correction method can shorten the image acquisition time by about one order of magnitude while ensuring a moderate accuracy of the depth image.

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Projects of Shaanxi Province
  • Youth Talents Promotion Program of Xi’an

Zitieren

APA

Wang, X., Zhang, T., Kang, Y., Li, W., & Liang, J. (2023). High-Flux Fast Photon-Counting 3D Imaging Based on Empirical Depth Error Correction. Photonics, 10(12), 1304. https://doi.org/10.3390/photonics10121304

Vancouver

Wang X, Zhang T, Kang Y, Li W, Liang J. High-Flux Fast Photon-Counting 3D Imaging Based on Empirical Depth Error Correction. Photonics. 2023;10(12):1304. doi:10.3390/photonics10121304

BibTeX
@article{Wang2023,
  author = {Wang, Xiaofang and Zhang, Tongyi and Kang, Yan and Li, Weiwei and Liang, Jintao},
  title = {High-Flux Fast Photon-Counting 3D Imaging Based on Empirical Depth Error Correction},
  journal = {Photonics},
  year = {2023},
  volume = {10},
  number = {12},
  pages = {1304},
  doi = {10.3390/photonics10121304}
}
Kostenlos starten →