Measurement of Paracetamol Concentration Using an Erbium-Doped Fiber Ring Cavity

Liliana Soares, Rosa Ana Pérez-Herrera, Susana Novais, António Ferreira, Susana Silva, Orlando Frazão

Photonics · 03.01.2023 · 10 (1) · 50

DOI: 10.3390/photonics10010050 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Photonics, online erschienen am 03.01.2023. Verfasst von Liliana Soares und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Portuguese funding agency, FCT—Fundação para a Ciência e a Tecnologia, FCT/MCTES (PIDDAC), Ministerio de Univesidades of Spain.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Process Analytical Technology (PAT) has been increasingly used in the pharmaceutical industry to monitor essential parameters in real-time during pharmaceutical processes. The concentration of Active Pharmaceutical Ingredients (APIs), such as paracetamol, is one of these parameters, and controlling its variations allows for optimization of the production process. In this study, a refractometric sensor, implemented by an interrogation system based on an Erbium-Doped Fiber Ring Cavity (EDFRC), was presented and experimentally demonstrated. The Cavity Ring proposed included a 1 × 3 coupler. One port of the coupler was used to increase the optical power of the system through a Fiber Bragg Grating (FBG), and the other two ports were used as sensing head and reference. The sensor detected variations of paracetamol concentration with a sensitivity of [(−1.00 ± 0.05) × 10−3] nW/(g/kg) and a resolution of 5.53 g/kg. The results demonstrate the potential of this technology as a possible non-invasive PAT tool.

Förderung

  • Portuguese funding agency, FCT—Fundação para a Ciência e a Tecnologia
  • FCT/MCTES (PIDDAC)
  • Ministerio de Univesidades of Spain
  • MCIN/AEI/10.13039/501100011033
  • FCT, Portugal

Zitieren

APA

Soares, L., Pérez-Herrera, R. A., Novais, S., Ferreira, A., Silva, S., & Frazão, O. (2023). Measurement of Paracetamol Concentration Using an Erbium-Doped Fiber Ring Cavity. Photonics, 10(1), 50. https://doi.org/10.3390/photonics10010050

Vancouver

Soares L, Pérez-Herrera RA, Novais S, Ferreira A, Silva S, Frazão O. Measurement of Paracetamol Concentration Using an Erbium-Doped Fiber Ring Cavity. Photonics. 2023;10(1):50. doi:10.3390/photonics10010050

BibTeX
@article{Soares2023,
  author = {Soares, Liliana and Pérez-Herrera, Rosa Ana and Novais, Susana and Ferreira, António and Silva, Susana and Frazão, Orlando},
  title = {Measurement of Paracetamol Concentration Using an Erbium-Doped Fiber Ring Cavity},
  journal = {Photonics},
  year = {2023},
  volume = {10},
  number = {1},
  pages = {50},
  doi = {10.3390/photonics10010050}
}
Kostenlos starten →