Technological and Physical Evaluation of a Radioprotective Marketed Cream to Assess Preformulation Studies for a Development of a Hospital Galenic Formulation
Pharmaceutics · 22.11.2026 · 18 (12) · 1519
DOI: 10.3390/pharmaceutics18121519 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pharmaceutics, online erschienen am 22.11.2026. Verfasst von Maria Rosaria Lauro und 6 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Multidisciplinary healthcare teams involved in radiological procedures are continuously exposed to ionizing radiation, particularly to the hands. Medical devices such as hand gloves and UltrabloXTM, an FDA-approved hands X-ray attenuating cream, may provide some protection. Unfortunately, leaded gloves can release lead through sweating, poising a risk of dermal absorbtion, while the marketed cream is expensive, and requires large amount to adequately cover the hands or gloves.
Objectives
Our goal is the development of a low-cost galenic topical device for X-ray hand protection based on bismuth oxide. Therefore, characterization studies of marketed cream and preformulation studies of a preliminary binary mixtures are conducted.
Methods
UltrabloXTM is characterized using rheological, thermal spectroscopic, and morphological analyses to identify its physicochemical properties; then, preliminary formulations containing shea butter and 70% (Bi70), 80% (Bi80), or 90% (Bi90) (w/w) of Bi2O3 are prepared and evaluated using the same analytical techniques.
Results
Bi80 and Bi90 show a protection comparable or superior to that of UltrabloXTM FTIR and DSC analyses confirmed the absence of chemical interactions between bismuth oxide and the lipid matrix used, indicating excellent physicochemical compatibility and structural integrity. The influence of Bi2O3 concentration on spreadability and structural organization are highlighted by rheological and SEM analyses. The better formulation is Bi80, providing an optimal balance between shielding performance, spreadability, and handling properties.
Conclusions
These results demonstrate the feasibility of producing a stable, effective, and cost-effective topical radioprotective preparation, suitable for hospital formulation and potential use in clinical radiology.
Zitieren
APA
Lauro, M. R., Acernese, F., Picerno, P., Aquino, R. P., D’Andria, P., Pilotti, I., & Romano, R. (2026). Technological and Physical Evaluation of a Radioprotective Marketed Cream to Assess Preformulation Studies for a Development of a Hospital Galenic Formulation. Pharmaceutics, 18(12), 1519. https://doi.org/10.3390/pharmaceutics18121519
Vancouver
Lauro MR, Acernese F, Picerno P, Aquino RP, D’Andria P, Pilotti I, et al. Technological and Physical Evaluation of a Radioprotective Marketed Cream to Assess Preformulation Studies for a Development of a Hospital Galenic Formulation. Pharmaceutics. 2026;18(12):1519. doi:10.3390/pharmaceutics18121519
BibTeX
@article{Lauro2026,
author = {Lauro, Maria Rosaria and Acernese, Fausto and Picerno, Patrizia and Aquino, Rita Patrizia and D’Andria, Pierluigi and Pilotti, Immacolata and Romano, Rocco},
title = {Technological and Physical Evaluation of a Radioprotective Marketed Cream to Assess Preformulation Studies for a Development of a Hospital Galenic Formulation},
journal = {Pharmaceutics},
year = {2026},
volume = {18},
number = {12},
pages = {1519},
doi = {10.3390/pharmaceutics18121519}
}
EUVIMED