Liver-Specific Methyl- and Bromine-Carrying [68Ga]Ga-THB-DAZA Tracers for Hepatobiliary PET Imaging: Radiochemistry and in ovo Pharmacokinetics
Pharmaceutics · 21.11.2026 · 18 (12) · 1509
DOI: 10.3390/pharmaceutics18121509 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pharmaceutics, online erschienen am 21.11.2026. Verfasst von Lukas Zehner und 7 weiteren Autor:innen. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Jena University Hospital, Thueringer Aufbaubank, Thueringer Universitaets-und Landesbibliothek Jena.
Abstract (Originalsprache)
Background/Objectives: The development of novel 68Ga complexes as radiotracers in nuclear medical imaging is of great importance for future precision diagnostics. Liver-specific 68Ga complexes may be used to visualize the liver-bile tract with positron emission tomography, thereby allowing the derivation of crucial information on liver function and bile flow, which are of particular relevance in liver-bile surgery. Based on the previously reported [68Ga]Ga-TEoS-DAZA, a structure–distribution relationship study on methylated and brominated tracers with potentially improved hepatobiliary pharmacokinetics was performed.
Methods
Nine ligands were prepared via a reductive amination procedure and characterized via 1H-, 13C NMR and MS. Radiolabeling with 68Ga was performed in HEPES buffer at room temperature, using cartridge purification and radio-HPLC for purity analysis. The biodistribution was visualized in embryonated ostrich eggs on a human PET scanner and quantified ex vivo. LogD values were determined via the shake-flask extraction method.
Results
Of the nine ligands, six ligands led to successful 68Ga complexation, with subsequent tracer isolation and in ovo testing in 4–5 embryos per tracer. One of the described 68Ga complexes showed statistically significantly higher liver uptake compared to the previously reported [68Ga]Ga-TEoS-DAZA. There was no clear correlation between the logD values and the liver uptake. An increased number of aromatic substituents or more than one bromo substituent per ring resulted in strongly reduced labeling efficiency.
Conclusions
Depending on their position on the phenyl ring, methyl and bromine substituents may lead to an increase in liver uptake, making these tracers potentially more suitable as hepatobiliary PET tracers.
Förderung
- Jena University Hospital
- Thueringer Aufbaubank
- Thueringer Universitaets-und Landesbibliothek Jena
Zitieren
APA
Zehner, L., Bussemer, L., Kühnel, C., Pomraenke, M., Gühne, F., Weber, B., Freesmeyer, M., & Greiser, J. (2026). Liver-Specific Methyl- and Bromine-Carrying [68Ga]Ga-THB-DAZA Tracers for Hepatobiliary PET Imaging: Radiochemistry and in ovo Pharmacokinetics. Pharmaceutics, 18(12), 1509. https://doi.org/10.3390/pharmaceutics18121509
Vancouver
Zehner L, Bussemer L, Kühnel C, Pomraenke M, Gühne F, Weber B, et al. Liver-Specific Methyl- and Bromine-Carrying [68Ga]Ga-THB-DAZA Tracers for Hepatobiliary PET Imaging: Radiochemistry and in ovo Pharmacokinetics. Pharmaceutics. 2026;18(12):1509. doi:10.3390/pharmaceutics18121509
BibTeX
@article{Zehner2026,
author = {Zehner, Lukas and Bussemer, Lisa and Kühnel, Christian and Pomraenke, Marta and Gühne, Falk and Weber, Birgit and Freesmeyer, Martin and Greiser, Julia},
title = {Liver-Specific Methyl- and Bromine-Carrying [68Ga]Ga-THB-DAZA Tracers for Hepatobiliary PET Imaging: Radiochemistry and in ovo Pharmacokinetics},
journal = {Pharmaceutics},
year = {2026},
volume = {18},
number = {12},
pages = {1509},
doi = {10.3390/pharmaceutics18121509}
}
EUVIMED