Development of an Electrospun Nanofibrous Wound Dressing Combining Arginine and Chlorhexidine for Targeted Management of Partial-Thickness Burns

Adrienn Kazsoki, Houssam Aaref Abboud, Dorka Boróka Simon, Anna Földes, Katalin Kristóf, Roland Petrény, Balázs Pinke, László Mészáros, Balázs Kürtösi, Romána Zelkó

Pharmaceutics · 16.11.2026 · 18 (11) · 1481

DOI: 10.3390/pharmaceutics18111481 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutics, online erschienen am 16.11.2026. Verfasst von Adrienn Kazsoki und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Partial-thickness burns require prompt infection control without compromising the cells that drive tissue repair. We report a fully electrospun bilayer dressing that assigns chlorhexidine digluconate (CHX) and L-arginine hydrochloride (ARG) to two separately formulated nanofibrous layers according to their different exposure requirements.

Methods

CHX was incorporated into a rapidly dissolving poly(vinyl alcohol) (PVA)–chitosan wound-contact layer and ARG into a more water-resistant PVA–silica hybrid layer obtained by sol–gel electrospinning of a tetraethyl orthosilicate (TEOS)-derived sol. Fibers were characterized by scanning electron microscopy, Fourier-transform infrared spectroscopy and X-ray powder diffraction (XRPD); release profiles were fitted with the Weibull model. Antibacterial activity was screened against four reference strains and nine clinical isolates, including multidrug-resistant strains; cytocompatibility was evaluated in 3T3 fibroblasts with the use of formulation-specific exposure protocols, and wound-healing potential with the use of an in vitro scratch assay.

Results

Drug loading preserved continuous nanofibrous morphology and XRPD showed no detectable crystalline drug fraction. CHX release was immediate, reaching 98.04 ± 0.41% within 5 min (t90 = 2.25 min), whereas ARG release was gradual, reaching 94.08 ± 2.14% at 120 min (t90 = 71.4 min). Full- and half-dose CHX fibers inhibited every strain tested, whereas ARG-containing and drug-free formulations showed no detectable antibacterial activity. The ARG-loaded layer maintained fibroblast viability comparable to the untreated control after 72 h of continuous exposure, while the CHX-loaded layer was well tolerated after single and repeated 5 min exposures. The ARG-loaded layer also increased fibroblast migration in the scratch assay.

Conclusions

Spatial and temporal compartmentalization therefore offers a rational basis for multifunctional partial-thickness burn dressings.

Zitieren

APA

Kazsoki, A., Abboud, H. A., Simon, D. B., Földes, A., Kristóf, K., Petrény, R., Pinke, B., Mészáros, L., Kürtösi, B., & Zelkó, R. (2026). Development of an Electrospun Nanofibrous Wound Dressing Combining Arginine and Chlorhexidine for Targeted Management of Partial-Thickness Burns. Pharmaceutics, 18(11), 1481. https://doi.org/10.3390/pharmaceutics18111481

Vancouver

Kazsoki A, Abboud HA, Simon DB, Földes A, Kristóf K, Petrény R, et al. Development of an Electrospun Nanofibrous Wound Dressing Combining Arginine and Chlorhexidine for Targeted Management of Partial-Thickness Burns. Pharmaceutics. 2026;18(11):1481. doi:10.3390/pharmaceutics18111481

BibTeX
@article{Kazsoki2026,
  author = {Kazsoki, Adrienn and Abboud, Houssam Aaref and Simon, Dorka Boróka and Földes, Anna and Kristóf, Katalin and Petrény, Roland and Pinke, Balázs and Mészáros, László and Kürtösi, Balázs and Zelkó, Romána},
  title = {Development of an Electrospun Nanofibrous Wound Dressing Combining Arginine and Chlorhexidine for Targeted Management of Partial-Thickness Burns},
  journal = {Pharmaceutics},
  year = {2026},
  volume = {18},
  number = {11},
  pages = {1481},
  doi = {10.3390/pharmaceutics18111481}
}
Kostenlos starten →