EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modeling of Residence Time Distributions of Twin-Screw Extrusion Processes Considering Various Screw Types

Vincent Kimmel iD, Dario Zöllig, Werner Hoheisel iD, Judith Winck iD, Markus Thommes iD

Pharmaceutics · 18.07.2026 · 18 (7) · 883

DOI: 10.3390/pharmaceutics18070883 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutics, online erschienen am 18.07.2026. Verfasst von Vincent Kimmel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 4422…. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Residence time in pharmaceutical hot-melt extrusion is a crucial process parameter affecting the quality attributes of a dosage form such as content uniformity, bioavailability and toxicity. There is a lack of knowledge about the influence of screw element types on the residence time distribution, which will be addressed in this study.

Methods

Different conveying and kneading elements will be characterized concerning their effect on the residence time using a co-rotating twin-screw extruder with a 28 mm screw diameter. Tracer experiments will be performed while concentration time profiles are measured via inline UV-Vis spectroscopy.

Results

The residence time distribution of all screw types is primarily related to the volume flow but independent of pressure. The two-compartment model of Reitz was utilized to describe the experimental data mathematically. Screw-type-specific dimensionless parameters were derived to quantify the axial mixing performance, as well as the effect on residence time.

Conclusions

The influence of different screw elements on the residence time in hot-melt extrusion processes was quantified using a dimensionless mixing volume and a dimensionless axial dispersion coefficient. The results meet the quantitative descriptions from the literature.

Schlagwörter

Stichwörter der Autor:innen

mechanistic modelingresidence time distributionscrew characteristicstwin-screw extruder

Autor:innen und Institutionen

  • Laboratory of Solids Process Engineering, Department of Biochemical and Chemical Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 44227 Dortmund, Germany.
  • INVITE GmbH, Drug Delivery Innovation Center, Chempark Building W32, Otto-Bayer-Str. 32, 51061 Cologne, Germany.
  • Bayer AG, 51368 Leverkusen, Germany.

ORCID-Profile: Vincent Kimmel, Werner Hoheisel, Judith Winck, Markus Thommes

Zitieren

APA

Kimmel, V., Zöllig, D., Hoheisel, W., Winck, J., & Thommes, M. (2026). Modeling of Residence Time Distributions of Twin-Screw Extrusion Processes Considering Various Screw Types. Pharmaceutics, 18(7), 883. https://doi.org/10.3390/pharmaceutics18070883

Vancouver

Kimmel V, Zöllig D, Hoheisel W, Winck J, Thommes M. Modeling of Residence Time Distributions of Twin-Screw Extrusion Processes Considering Various Screw Types. Pharmaceutics. 2026;18(7):883. doi:10.3390/pharmaceutics18070883

BibTeX
@article{Kimmel2026,
  author = {Kimmel, Vincent and Zöllig, Dario and Hoheisel, Werner and Winck, Judith and Thommes, Markus},
  title = {Modeling of Residence Time Distributions of Twin-Screw Extrusion Processes Considering Various Screw Types},
  journal = {Pharmaceutics},
  year = {2026},
  volume = {18},
  number = {7},
  pages = {883},
  doi = {10.3390/pharmaceutics18070883}
}
Kostenlos starten →