EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Merging Real-Time NIR and Process Parameter Measurements in a Fluidized Bed Granulation Process to Predict Particle Size

Ozren Jovic, Marcus O'Mahony iD, Samuel Solomon iD, David Egan, Chris O'Callaghan, Caroline McCormack, Ian Jones, Patrick Cronin, Gavin M Walker, Rabah Mouras

Pharmaceutics · 29.05.2025 · 17 (6) · 720

DOI: 10.3390/pharmaceutics17060720 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceutics, online erschienen am 29.05.2025. Verfasst von Ozren Jovic und 9 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Manufacturing Technology Centre, Bernal Institute, Department of Chemical Sciences, University of Limerick, V94 T9PX Limerick, Ireland. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Enterprise Ireland, PMTC Core research, Innovation Partnership programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Controlling the critical quality attributes (CQAs), such as granule moisture level and particle size distribution, that impact product performance is essential for ensuring product quality in medicine manufacture. Oral solid dosage forms, such as tablets, often require appropriate powder flow for compaction and filling. Spray-dried fluidized bed granulation (FBG) is a key unit operation in the preparation of granulated powders. The determination of particle sizes in FBG using near-infrared spectroscopy (NIR) has been considered in the literature. Herein, for the first time, NIR is combined with process parameters to achieve improved prediction of the particle sizes in FBG.

Methods

An inline model for particle size determination using both NIR and FBG process parameters was developed using the partial least square (PLS) method, or ‘merged-PLS model’. The particle size was predicted at the end point of the process, i.e., the last 10% of the particle-size data for each batch run. An additional two analyses included a merged-PLS model with 12 batches: (1) where nine batches were training and three batches were a test set; and (2) where 11 batches were training and one was a test batch.

Results

For all considered particle size fractions, Dv10, Dv25, Dv50, Dv75, and Dv90, an improved root-mean-squared error of prediction (RMSEP) is obtained for the merged-PLS model compared to the NIR-only PLS model and compared to the process parameters alone model. Improved RMSEP is also achieved for the additional two analyses.

Conclusions

The improved prediction performance of endpoint particle sizes by the merged-PLS model can help to enhance both the process understanding and the overall control of the FBG process.

Schlagwörter

Stichwörter der Autor:innen

NIR spectroscopyPLSchemometricscritical quality attributes (CQAs)fluid bed granulationmachine learning (ML)particle sizepredictive modelingprocess analytical technology (PAT)

Autor:innen und Institutionen

  • Pharmaceutical Manufacturing Technology Centre, Bernal Institute, Department of Chemical Sciences, University of Limerick, V94 T9PX Limerick, Ireland.
  • Dairy Processing Technology Centre, Bernal Institute, Department of Chemical Sciences, University of Limerick, V94 T9PX Limerick, Ireland.
  • InnoGlobal Technology, Ravenscourt Campus, D18 K599 Dublin, Ireland.

ORCID-Profile: Marcus O'Mahony, Samuel Solomon

Förderung

  • Enterprise Ireland
  • PMTC Core research
  • Innovation Partnership programme
  • Capital Equipment call

Zitieren

APA

Jovic, O., O'Mahony, M., Solomon, S., Egan, D., O'Callaghan, C., McCormack, C., Jones, I., Cronin, P., Walker, G. M., & Mouras, R. (2025). Merging Real-Time NIR and Process Parameter Measurements in a Fluidized Bed Granulation Process to Predict Particle Size. Pharmaceutics, 17(6), 720. https://doi.org/10.3390/pharmaceutics17060720

Vancouver

Jovic O, O'Mahony M, Solomon S, Egan D, O'Callaghan C, McCormack C, et al. Merging Real-Time NIR and Process Parameter Measurements in a Fluidized Bed Granulation Process to Predict Particle Size. Pharmaceutics. 2025;17(6):720. doi:10.3390/pharmaceutics17060720

BibTeX
@article{Jovic2025,
  author = {Jovic, Ozren and O'Mahony, Marcus and Solomon, Samuel and Egan, David and O'Callaghan, Chris and McCormack, Caroline and Jones, Ian and Cronin, Patrick and Walker, Gavin M and Mouras, Rabah},
  title = {Merging Real-Time NIR and Process Parameter Measurements in a Fluidized Bed Granulation Process to Predict Particle Size},
  journal = {Pharmaceutics},
  year = {2025},
  volume = {17},
  number = {6},
  pages = {720},
  doi = {10.3390/pharmaceutics17060720}
}
Kostenlos starten →