EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simultaneous Quantification of Colistin A and B in Human Plasma Using a Small Volume with a High-Throughput LC-MS/MS Method

Jimin Yoon iD, Won Gun Kwack iD, Kyung-Tae Lee iD, Eunseo Song iD, Hyeon Su Kim, Ki-Ho Park iD, Eun Kyoung Chung iD

Pharmaceuticals · 12.06.2026 · 19 (6) · 924

DOI: 10.3390/ph19060924 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmaceuticals, online erschienen am 12.06.2026. Verfasst von Jimin Yoon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, College of Pharmacy, Kyung Hee University, Seoul 02447, Republic of Korea. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Kyung Hee University, Ministry of Food and Drug Safety.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: Colistin is a complex polymyxin antibiotic with a narrow therapeutic window and significant interindividual pharmacokinetic variability, necessitating precise concentration monitoring. Current analytical methods often utilize colistin mixtures or require large sample volumes, potentially limiting the precision and resolution of individual component quantification. This study aimed to develop a sensitive and component-specific bioanalytical assay for the simultaneous quantification of colistin A and colistin B in human plasma.

Methods

A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed using pure, component-specific reference standards to ensure rigorous independent quantification of each component. Analytes were efficiently extracted from a small volume of plasma (50 µL) using solid-phase extraction. Chromatographic separation was achieved on a C18 column with a total runtime of 4 min, and detection was performed using negative-ion multiple reaction monitoring (MRM).

Results

Calibration curves showed excellent linearity over a range of 0.1–20 µg/mL for both colistin A and B (R2 > 0.99). The precision (%CV ≤ 8.8%) and accuracy (86.4–105.7%) for both components met the predefined regulatory criteria. This method was clinically validated using 60 plasma samples from 15 patients, demonstrating its applicability for capturing individual concentration–time profiles within the clinically relevant range (0.323–19.579 µg/mL for colistin A and 0.065–6.132 µg/mL for colistin B).

Conclusions

This validated bioanalytical assay enables precise clinical pharmacokinetic assessments in a high-throughput workflow using a small plasma volume. Therefore, it serves as a practical tool for therapeutic drug monitoring (TDM)-guided dose optimization and further clinical investigations of colistin therapy.

Schlagwörter

Stichwörter der Autor:innen

LC–MS/MScolistincolistin Acolistin Bpharmacokineticstherapeutic drug monitoring

Autor:innen und Institutionen

  • Department of Pharmacy, College of Pharmacy, Kyung Hee University, Seoul 02447, Republic of Korea.
  • Division of Pulmonary, Allergy and Critical Care Medicine, Kyung Hee University Hospital, Seoul 02447, Republic of Korea.
  • Kyung Hee Drug Analysis Center, College of Pharmacy, Kyung Hee University, Seoul 02447, Republic of Korea.
  • Department of Biomedical and Pharmaceutical Sciences, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea.
  • Department of Regulatory Science, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea.
  • Institutes of Regulatory Innovation Through Science (IRIS), Kyung Hee University, Seoul 02447, Republic of Korea.

ORCID-Profile: Jimin Yoon, Won Gun Kwack, Kyung-Tae Lee, Eunseo Song, Ki-Ho Park, Eun Kyoung Chung

Förderung

  • National Research Foundation of Korea
  • Kyung Hee University
  • Ministry of Food and Drug Safety

Zitieren

APA

Yoon, J., Kwack, W. G., Lee, K. T., Song, E., Kim, H. S., Park, K. H., & Chung, E. K. (2026). Simultaneous Quantification of Colistin A and B in Human Plasma Using a Small Volume with a High-Throughput LC-MS/MS Method. Pharmaceuticals, 19(6), 924. https://doi.org/10.3390/ph19060924

Vancouver

Yoon J, Kwack WG, Lee KT, Song E, Kim HS, Park KH, et al. Simultaneous Quantification of Colistin A and B in Human Plasma Using a Small Volume with a High-Throughput LC-MS/MS Method. Pharmaceuticals. 2026;19(6):924. doi:10.3390/ph19060924

BibTeX
@article{Yoon2026,
  author = {Yoon, Jimin and Kwack, Won Gun and Lee, Kyung-Tae and Song, Eunseo and Kim, Hyeon Su and Park, Ki-Ho and Chung, Eun Kyoung},
  title = {Simultaneous Quantification of Colistin A and B in Human Plasma Using a Small Volume with a High-Throughput LC-MS/MS Method},
  journal = {Pharmaceuticals},
  year = {2026},
  volume = {19},
  number = {6},
  pages = {924},
  doi = {10.3390/ph19060924}
}
Kostenlos starten →