EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Detection of Marek’s Disease Virus Using Cold-Chain-Independent Lyophilized LAMP Beads for Closed-Tube, Single-Step, Fluorometric LAMP and Penn-RAMP Assays

Mohamed El-Tholoth, Dina Mohammed, Rabiha Seboussi

Pathogens · 07.11.2026 · 15 (11) · 1171

DOI: 10.3390/pathogens15111171 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pathogens, online erschienen am 07.11.2026. Verfasst von Mohamed El-Tholoth und 2 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Higher Colleges of Technology.

AbstractBibliografische AngabenZitieren

Abstract (Originalsprache)

Background/Objectives: Marek’s disease virus (MDV) is a highly contagious oncogenic virus in chickens, which causes immunosuppression and lymphoproliferative tumors leading to substantial economic losses to the poultry industry. Early, accurate and accessible detection is essential for effective disease surveillance and control. Conventional polymerase chain reaction (PCR)-based approaches are reliable for diagnosis but their reliance on expensive lab equipment and skilled operators limits their use in resource-limited and decentralized settings. The objective of this study was to develop two rapid, inexpensive, and user-friendly fluorometric isothermal amplification assays for MDV detection.

Methods

A loop-mediated isothermal amplification (LAMP) assay and a nested isothermal amplification (Penn-RAMP) assay were developed for MDV detection. Penn-RAMP assay combines recombinase polymerase amplification (RPA) at 38 °C and LAMP at 65 °C in a single closed tube. Both assays were conducted using cold-chain-free lyophilized LAMP reagent beads for simplified storage and transportation, thereby increasing their applicability for molecular diagnostics at the point of need. The performance of these assays was compared to quantitative PCR (qPCR).

Results

The sensitivity of the LAMP assay was 100 copies of genomic DNA per reaction. The closed-tube RAMP assay achieved a 10-fold lower limit of detection (10 genomic copies/reaction) compared to both LAMP and qPCR. The clinical performance of the developed assays showed 100% sensitivity and specificity against the qPCR.

Conclusions

Our assays offer a rapid, sensitive, specific and simple method for MDV molecular diagnosis, especially for resource-limited veterinary diagnostic laboratories.

Förderung

  • Higher Colleges of Technology

Zitieren

APA

El-Tholoth, M., Mohammed, D., & Seboussi, R. (2026). Rapid Detection of Marek’s Disease Virus Using Cold-Chain-Independent Lyophilized LAMP Beads for Closed-Tube, Single-Step, Fluorometric LAMP and Penn-RAMP Assays. Pathogens, 15(11), 1171. https://doi.org/10.3390/pathogens15111171

Vancouver

El-Tholoth M, Mohammed D, Seboussi R. Rapid Detection of Marek’s Disease Virus Using Cold-Chain-Independent Lyophilized LAMP Beads for Closed-Tube, Single-Step, Fluorometric LAMP and Penn-RAMP Assays. Pathogens. 2026;15(11):1171. doi:10.3390/pathogens15111171

BibTeX
@article{ElTholoth2026,
  author = {El-Tholoth, Mohamed and Mohammed, Dina and Seboussi, Rabiha},
  title = {Rapid Detection of Marek’s Disease Virus Using Cold-Chain-Independent Lyophilized LAMP Beads for Closed-Tube, Single-Step, Fluorometric LAMP and Penn-RAMP Assays},
  journal = {Pathogens},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {1171},
  doi = {10.3390/pathogens15111171}
}
Kostenlos starten →