Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea
Pathogens · 20.08.2026 · 15 (8) · 872
DOI: 10.3390/pathogens15080872 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Pathogens, online erschienen am 20.08.2026. Verfasst von Alexandra Martín-Ramírez und 14 weiteren Autor:innen. Beteiligte Einrichtung: Malaria and Emerging Parasites Laboratory, National Center for Microbiology, Institute of Health Carlos III, 28222 Madrid, Spain. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Molecular Diagnostic Techniques, Plasmodium falciparum, Malaria. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Health Carlos III, Spanish Agency for International Development Cooperation, Centro de Investigación Biomédica en Red.
Abstract (Originalsprache)
Malaria diagnosis in Equatorial Guinea (EG) is based on conventional microscopy, sometimes combined with rapid diagnostic tests (RDTs). However, some laboratories, such as the Baney Research Laboratory (BRL) have implemented molecular technology for the diagnosis of infectious diseases. This study aimed to evaluate, for the first time in EG, a LAMP method for malaria diagnosis, comparing its performance with conventional microscopy performed in EG and with LAMP and PCR diagnostic methods performed at the National Centre of Tropical Medicine (NCTM), Spain. A total of 178 blood samples (including P. falciparum samples and malaria-negative controls) were evaluated using Dual-LAMP-Pspp and Nested-PCR-Pf in Equatorial Guinea. Dual-LAMP-Pspp performed at the BRL showed sensitivity and specificity values of 97.28% and 100%, respectively, for malaria diagnosis, with no differences between colorimetric and fluorescence-based result readings. Meanwhile, Nested-PCR-Pf showed a sensitivity of 87.07% and a specificity of 100%. Comparison of parasite densities determined by Dual-LAMP-Pspp and conventional microscopy showed a significant moderate negative correlation (correlation coefficient = −0.584). The comparison of Dual-LAMP-Pspp results between BRL and NCTM showed a kappa coefficient of 0.93, whereas the kappa coefficient of the Nested-PCR-Pf assay was 0.70. These findings indicate that Dual-LAMP-Pspp and Nested-PCR-Pf are suitable methods for malaria diagnosis in EG. However, the Dual-LAMP-Pspp assay was easy to perform and interpret and provided results in a shorter time than Nested-PCR-Pf.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Malaria and Emerging Parasites Laboratory, National Center for Microbiology, Institute of Health Carlos III, 28222 Madrid, Spain.
- Centro de Investigación Biomédica en Red de Enfermedades Infecciosas, Instituto de Salud Carlos III, 28029 Madrid, Spain.
- Baney Research Laboratory, Baney P.O. Box 338, Equatorial Guinea.
- Malariology Unit, Institute of Tropical Medicine of Antwerp, 2000 Antwerp, Belgium.
- National Center of Tropical Medicine, Institute of Health Carlos III, 28029 Madrid, Spain.
- National Malaria Programme, Ministry of Health and Social Welfare, Government of the Republic of Equatorial Guinea, Malabo, Equatorial Guinea.
ORCID-Profile: Alexandra Martín-Ramírez, Agustín Benito, José Miguel Rubio, Pedro Berzosa
Förderung
- Institute of Health Carlos III
- Spanish Agency for International Development Cooperation
- Centro de Investigación Biomédica en Red
- Instituto de Salud Carlos III
- CIBERINFEC, ISCIII
Zitieren
APA
Martín-Ramírez, A., Mikumu Alogo, T., Palacios, V., Kobe Elonga, M., Mangue, V., Molina-de la Fuente, I., González Mora, V., Lanza-Suárez, M., Rodríguez-Galet, A., Riloha Rivas, M., Ncogo, P., Benito, A., Rubio, J. M., Nyakarungu, E., & Berzosa, P. (2026). Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea. Pathogens, 15(8), 872. https://doi.org/10.3390/pathogens15080872
Vancouver
Martín-Ramírez A, Mikumu Alogo T, Palacios V, Kobe Elonga M, Mangue V, Molina-de la Fuente I, et al. Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea. Pathogens. 2026;15(8):872. doi:10.3390/pathogens15080872
BibTeX
@article{MartnRamrez2026,
author = {Martín-Ramírez, Alexandra and Mikumu Alogo, Teodora and Palacios, Victoria and Kobe Elonga, Monserrat and Mangue, Victoria and Molina-de la Fuente, Irene and González Mora, Vicenta and Lanza-Suárez, Marta and Rodríguez-Galet, Ana and Riloha Rivas, Matilde and Ncogo, Policarpo and Benito, Agustín and Rubio, José Miguel and Nyakarungu, Elizabeth and Berzosa, Pedro},
title = {Loop-Mediated Isothermal Amplification (LAMP) Assessment for Malaria Diagnosis in Equatorial Guinea},
journal = {Pathogens},
year = {2026},
volume = {15},
number = {8},
pages = {872},
doi = {10.3390/pathogens15080872}
}
EUVIMED