EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cardiovascular, Cerebral, and Performance Responses to Q-Collar™ Use in a 5 km Cycling Time Trial: A Randomized Crossover Trial

Kelsey Bourbeau, Andrew Wells, Zac Simon, Mark Hecimovich, Ben Boezinger, Issa Sullivan, Dylan Darsidan, Terence Moriarty

Oxygen · 04.11.2026 · 6 (4) · 38

DOI: 10.3390/oxygen6040038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oxygen, online erschienen am 04.11.2026. Verfasst von Kelsey Bourbeau und 7 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: The Q-Collar™, a device that mildly compresses the jugular veins to increase cranial fluid volume, has been investigated for potential protection against brain changes associated with concussive and subconcussive impacts during athletic events involving physical contact. However, physiological responses using this device as well as the physical and cognitive performance outcomes remain unclear. Therefore, the purpose of the study was to investigate hemodynamic, metabolic, prefrontal cortex oxygenation (PFC-O2Hb), choice reaction time (CRT) via the Stroop test, and time-to-completion outcomes with and without Q-Collar™ use.

Methods

Eleven male participants qualified for inclusion into the repeated-measures randomized crossover study following an incremental cycling cardiopulmonary exercise test. Upon qualification, participants visited the lab twice to complete a 5 km cycling time trial with and without Q-Collar™ use. Each visit was separated by at least 72 h.

Results

No statistically significant differences in hemodynamic, blood lactate (BLa−), PFC-O2Hb, or time-to-completion outcomes were found comparing Q-Collar™ use to a Control condition. However, improved CRT was found during, immediately following, and 10 min post the time trial relative to a resting CRT baseline.

Conclusions

No statistically significant acute differences were detected between Q-Collar™ and Control for measured outcomes during a 5 km cycling time trial in this exploratory study. Smaller effects cannot be excluded, and because jugular compression was not verified during exercise, these findings reflect the effect of wearing a manufacturer-fitted Q-Collar™ rather than verified jugular compression. CRT was shorter during and after exercise relative to rest in both conditions, although repeated-testing effects cannot be excluded.

Zitieren

APA

Bourbeau, K., Wells, A., Simon, Z., Hecimovich, M., Boezinger, B., Sullivan, I., Darsidan, D., & Moriarty, T. (2026). Cardiovascular, Cerebral, and Performance Responses to Q-Collar™ Use in a 5 km Cycling Time Trial: A Randomized Crossover Trial. Oxygen, 6(4), 38. https://doi.org/10.3390/oxygen6040038

Vancouver

Bourbeau K, Wells A, Simon Z, Hecimovich M, Boezinger B, Sullivan I, et al. Cardiovascular, Cerebral, and Performance Responses to Q-Collar™ Use in a 5 km Cycling Time Trial: A Randomized Crossover Trial. Oxygen. 2026;6(4):38. doi:10.3390/oxygen6040038

BibTeX
@article{Bourbeau2026,
  author = {Bourbeau, Kelsey and Wells, Andrew and Simon, Zac and Hecimovich, Mark and Boezinger, Ben and Sullivan, Issa and Darsidan, Dylan and Moriarty, Terence},
  title = {Cardiovascular, Cerebral, and Performance Responses to Q-Collar™ Use in a 5 km Cycling Time Trial: A Randomized Crossover Trial},
  journal = {Oxygen},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {38},
  doi = {10.3390/oxygen6040038}
}