EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Radiological and Surface Topography Criteria: A Comparative Study Within the Rigo Classification

Natalie Schmidt, Adam Thiessen, Marissa Selthafner, Kai Yang, Xue-Cheng Liu

Osteology · 12.11.2026 · 6 (4) · 25

DOI: 10.3390/osteology6040025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Osteology, online erschienen am 12.11.2026. Verfasst von Natalie Schmidt und 4 weiteren Autor:innen. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: No descriptive data have been reported for the radiological criteria used in the Rigo classification system (RCS) beyond the curve pattern. This study aims to quantify, compare, and correlate the criteria using X-ray and surface topography (ST).

Methods

Three observers classified ST and X-ray AIS images according to the RCS. One observer then measured the following RCS criteria on both ST and X-ray, twice for each image, and averaged the measurements: Cobb angle, T1 offset, T1 tilt, transition point (TP) offset, L3 tilt, L4 tilt, L5 tilt, and pelvic shift.

Results

Between ST and X-ray, the TP offset showed no significant differences (p > 0.05) and very strong correlation (r = 0.90, p < 0.0001). T1 offset and pelvic shift had no significant differences between ST and X-ray (p > 0.05) and had moderate to strong correlation (r = 0.59 to 0.73, p < 0.001). The Cobb angle showed moderate correlation for all types (r = 0.67, p < 0.0001), but showed significant difference for the B and E types. All other criteria demonstrated strong to very strong correlation between ST and X-ray (r = 0.76 to 0.90, p < 0.05), except for T1 tilt. Significant differences existed between ST and X-ray for the following criteria and types: T1 tilt (B, C); L3 tilt (B, E); L4 tilt (A, B); and L5 tilt (A). All ST criteria demonstrated moderate to good agreement (ICC = 0.57 to 0.88, p < 0.001), except T1 tilt (ICC = 0.14).

Conclusions

Both ST and X-ray provide several valuable RCS criteria, with TP offset, T1 offset, and pelvic shift showing no significant differences between imaging systems. These ST-based parameters may provide complementary value to traditional radiological criteria within the RCS framework.

Zitieren

APA

Schmidt, N., Thiessen, A., Selthafner, M., Yang, K., & Liu, X. (2026). Radiological and Surface Topography Criteria: A Comparative Study Within the Rigo Classification. Osteology, 6(4), 25. https://doi.org/10.3390/osteology6040025

Vancouver

Schmidt N, Thiessen A, Selthafner M, Yang K, Liu X. Radiological and Surface Topography Criteria: A Comparative Study Within the Rigo Classification. Osteology. 2026;6(4):25. doi:10.3390/osteology6040025

BibTeX
@article{Schmidt2026,
  author = {Schmidt, Natalie and Thiessen, Adam and Selthafner, Marissa and Yang, Kai and Liu, Xue-Cheng},
  title = {Radiological and Surface Topography Criteria: A Comparative Study Within the Rigo Classification},
  journal = {Osteology},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {25},
  doi = {10.3390/osteology6040025}
}
Kostenlos starten →