EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Evaluation of Primary Stability between Different Diameters Multi-Scale Roughness Dental Implant by Solid Rigid Polyurethane Simulation

Margherita Tumedei, Morena Petrini, Alessandro Cipollina, Mariastella Di Carmine, Adriano Piattelli, Antonio Cucurullo, Giovanna Iezzi

Osteology · 2021

DOI: 10.3390/osteology1010006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Osteology, 2021. Verfasst von Margherita Tumedei und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Implant primary stability is determined by screw characteristics and surgical procedure. The aim of the present study was to evaluate, on a polyurethane model, the insertion torque (IT), removal torque (RT), and resonance frequency analysis (RFA) of multi-scale roughness dental implants of different diameters.

Methods

Two implant sizes were tested on two polyurethane blocks (20 pounds per cubic foot (PCF) and 30 PCF): 3.0 diameter and 13 mm length and 5.0 diameter and 13 mm length. The IT, RT, and RFA were assessed.

Results

A significant difference of IT and RT was present in favor of wider implants at both polyurethane densities. No statistical difference was present between the 5.0 diameter and 3.0 diameter implants at both polyurethane densities. A statistically increased RFA was reported for 5.0 implant 30 PCF polyurethane blocks.

Conclusions

Multi-scale roughness dental implants of both diameters showed high insertion torque and primary stability on polyurethane blocks, which is valuable for implant loading protocols.

Zitieren

APA

Tumedei, M., Petrini, M., Cipollina, A., Carmine, M. D., Piattelli, A., Cucurullo, A., & Iezzi, G. (2021). Comparative Evaluation of Primary Stability between Different Diameters Multi-Scale Roughness Dental Implant by Solid Rigid Polyurethane Simulation. Osteology. https://doi.org/10.3390/osteology1010006

Vancouver

Tumedei M, Petrini M, Cipollina A, Carmine MD, Piattelli A, Cucurullo A, et al. Comparative Evaluation of Primary Stability between Different Diameters Multi-Scale Roughness Dental Implant by Solid Rigid Polyurethane Simulation. Osteology. 2021. doi:10.3390/osteology1010006

BibTeX
@article{Tumedei2021,
  author = {Tumedei, Margherita and Petrini, Morena and Cipollina, Alessandro and Carmine, Mariastella Di and Piattelli, Adriano and Cucurullo, Antonio and Iezzi, Giovanna},
  title = {Comparative Evaluation of Primary Stability between Different Diameters Multi-Scale Roughness Dental Implant by Solid Rigid Polyurethane Simulation},
  journal = {Osteology},
  year = {2021},
  doi = {10.3390/osteology1010006}
}
Kostenlos starten →