EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design of a Highly Sensitive Detector Using a Ternary Photonic Crystal (PC) Based on Titanium Nitride Sandwiched between Si and SiO2 for the Creatinine Concentration Detection in the Blood Serum

Malek G. Daher, Youssef Trabelsi, Abinash Panda, Ashot H. Gevorgyan, Khedr M. Abohassan, Lassaad K. Smirani, Baraa Riyadh Altahan, Ahmed Nabih Zaki Rashed

Optics · 29.11.2022 · 3 (4) · 447-461

DOI: 10.3390/opt3040038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics, online erschienen am 29.11.2022. Verfasst von Malek G. Daher und 7 weiteren Autor:innen. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Khalid University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

It is very important to design a rapid and sensitive device for the creatinine concentration detection due to it being one of the most considerable benchmarks for efficient kidney working. Here, a novel biophotonic sensor using one-dimensional ternary PC based on Si/TiN/SiO2 layers is proposed for the creatinine concentration detection in a blood serum sample. A central cavity layer is inserted between two equal periodic numbers. The blood sample can be infiltrated in the cavity layer with various creatinine concentrations. Based on the technique of transfer matrix, the transmittance spectra properties are investigated. The influences of variation of the incidence angle for both TE and TM polarizations and the cavity layer thickness are carefully investigated to attain the best sensitivity of the biophotonic detector. A high sensitivity of 938.02 nm/RIU is realized for the suggested detector, which is comparable to most recent works published in this area. Moreover, the proposed sensor has an inexpensive cost, real-time detection, and simple structure, which is helpful to the industrial design using low-cost product nanofabrication techniques. Based on above-mentioned outcomes, our biosensor candidate is a suitable and effective device for the detection of creatinine concentration, and it can use for any biological sample.

Förderung

  • King Khalid University

Zitieren

APA

Daher, M. G., Trabelsi, Y., Panda, A., Gevorgyan, A. H., Abohassan, K. M., Smirani, L. K., Altahan, B. R., & Rashed, A. N. Z. (2022). Design of a Highly Sensitive Detector Using a Ternary Photonic Crystal (PC) Based on Titanium Nitride Sandwiched between Si and SiO2 for the Creatinine Concentration Detection in the Blood Serum. Optics, 3(4), 447-461. https://doi.org/10.3390/opt3040038

Vancouver

Daher MG, Trabelsi Y, Panda A, Gevorgyan AH, Abohassan KM, Smirani LK, et al. Design of a Highly Sensitive Detector Using a Ternary Photonic Crystal (PC) Based on Titanium Nitride Sandwiched between Si and SiO2 for the Creatinine Concentration Detection in the Blood Serum. Optics. 2022;3(4):447-461. doi:10.3390/opt3040038

BibTeX
@article{Daher2022,
  author = {Daher, Malek G. and Trabelsi, Youssef and Panda, Abinash and Gevorgyan, Ashot H. and Abohassan, Khedr M. and Smirani, Lassaad K. and Altahan, Baraa Riyadh and Rashed, Ahmed Nabih Zaki},
  title = {Design of a Highly Sensitive Detector Using a Ternary Photonic Crystal (PC) Based on Titanium Nitride Sandwiched between Si and SiO2 for the Creatinine Concentration Detection in the Blood Serum},
  journal = {Optics},
  year = {2022},
  volume = {3},
  number = {4},
  pages = {447--461},
  doi = {10.3390/opt3040038}
}
Kostenlos starten →