A Comparison of the Interstitial and Blood Glucose Responses Following Consumption of Different Carbohydrate-Containing Beverages in Humans: A Randomised Controlled Trial
Nutrients · 22.06.2026 · 18 (12) · 2033
DOI: 10.3390/nu18122033 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Nutrients, online erschienen am 22.06.2026. Verfasst von Ross Hamilton und 2 weiteren Autor:innen. Beteiligte Einrichtung: Applied Sport, Technology, Exercise and Medicine Research Centre, Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK. Hauptthemen laut MEDLINE: Blood Glucose, Dietary Carbohydrates, Beverages. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Supersapiens, Team Novo Nordisk Foundation, Swansea University.
Abstract (Originalsprache)
Objectives
This study investigated the relationship between interstitial and blood glucose concentrations following ingestion of carbohydrate-containing drinks differing in carbohydrate amount, osmolarity, and glycaemic index.
Methods
Ten healthy adults (nine male; age: 22 ± 1 y; height: 177 ± 12 cm; weight: 75 ± 14 kg) completed a double-blind, randomised cross-over study with seven beverage trials varying in carbohydrate (CHO) characteristics. Blood samples were collected at rest and over two hours, while interstitial glucose ([iG]) was recorded using a continuous glucose monitor (Supersapiens, Atlanta, USA). Glycaemic metrics and mean absolute relative difference (MARD) were calculated for hypoglycaemic, euglycaemic, and hyperglycaemic ranges. Data were analysed using repeated-measures ANOVA with Bonferroni correction and paired t-tests (p ≤ 0.05).
Results
Interstitial and blood glucose concentrations were similar at baseline but diverged post-ingestion. MARD varied by glucose rate and direction, exceeding 20% during rapid declines (>2 mg/dL/min), where [iG] underestimated [BG] by −7.3 ± 27.1 mg/dL. Accuracy was highest during stable glucose (MARD = 10.5 ± 8.6%). Carbohydrate amount and glycaemic index influenced peak glucose, whereas beverage concentration (5–20%) had minimal effect when CHO amount was fixed, though variation in CGM agreement appeared during post-peak declines.
Conclusions
CGM tracked blood glucose overall but showed reduced accuracy during rapid falls or hypoglycaemia. Carbohydrate properties influenced glycaemic response but not sensor agreement when CHO load was constant. Glucose rate and direction of change are key considerations for interpreting CGM data in research and applied settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Applied Sport, Technology, Exercise and Medicine Research Centre, Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK.
- Medical School, Swansea University, Swansea SA1 8EN, UK.
- Health Technology and Solutions Interdisciplinary Research Institute, Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK.
ORCID-Profile: Ross Hamilton, Richard M Bracken
Förderung
- Supersapiens
- Team Novo Nordisk Foundation
- Swansea University
- Supersapiens Inc.
- Novo Nordisk Foundation
Zitieren
APA
Hamilton, R., Bain, S. C., & Bracken, R. M. (2026). A Comparison of the Interstitial and Blood Glucose Responses Following Consumption of Different Carbohydrate-Containing Beverages in Humans: A Randomised Controlled Trial. Nutrients, 18(12), 2033. https://doi.org/10.3390/nu18122033
Vancouver
Hamilton R, Bain SC, Bracken RM. A Comparison of the Interstitial and Blood Glucose Responses Following Consumption of Different Carbohydrate-Containing Beverages in Humans: A Randomised Controlled Trial. Nutrients. 2026;18(12):2033. doi:10.3390/nu18122033
BibTeX
@article{Hamilton2026,
author = {Hamilton, Ross and Bain, Stephen C and Bracken, Richard M},
title = {A Comparison of the Interstitial and Blood Glucose Responses Following Consumption of Different Carbohydrate-Containing Beverages in Humans: A Randomised Controlled Trial},
journal = {Nutrients},
year = {2026},
volume = {18},
number = {12},
pages = {2033},
doi = {10.3390/nu18122033}
}
EUVIMED