EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY 4.0

Fluid Shifts and Muscle Loss in Critical Care: Accuracy of Ultrasound Versus Bioelectrical Impedance Analysis

Gintarė Šostakaitė iD, Martyna Jauniškytė iD, Dominykas Budrys, Kastytis Budrevičius, Erika Šalčiūtė-Šimėnė iD, Marija Svetikienė, Tomas Jovaiša iD, Tadas Žvirblis iD, Andrius Klimašauskas, Jūratė Šipylaitė

Nutrients · 21.06.2026 · 18 (12) · 2019

DOI: 10.3390/nu18122019 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Nutrients, online erschienen am 21.06.2026. Verfasst von Gintarė Šostakaitė und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinic of Anaesthesiology and Intensive Care, Faculty of Medicine, Vilnius University, LT-01513 Vilnius, Lithuania. Hauptthemen laut MEDLINE: Electric Impedance, Critical Care, Fluid Shifts, Water-Electrolyte Balance. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Critically ill patients experience rapid muscle wasting during their ICU stay. Ultrasound (US) and bioelectrical impedance analysis (BIA) are widely used to assess muscle mass; however, their accuracy may be affected by fluid balance alterations. This study aimed to compare the reliability of US and BIA in detecting muscle loss under varying fluid balance conditions in ICU patients.

Methods

In this prospective observational study, adult ICU patients with an ICU stay of ≥7 days were evaluated on Days 1, 5, and 7. Muscle thickness was measured using US, and phase angle (PhA) using BIA. Cumulative fluid balance, C-reactive protein (CRP), and lactate levels were recorded. Patients were stratified according to cumulative fluid balance.

Results

A total of 143 ICU patients were included in the final analysis. US demonstrated a progressive decrease in muscle thickness (−3.54% ± 10.90% from Day 1 to Day 5 and −7.56% ± 11.82% from Day 1 to Day 7 (both p < 0.0001)), whereas BIA showed no significant change in PhA. Positive fluid balance significantly reduced PhA compared with the negative balance group, p < 0.001, whereas no statistically significant effect on US measurements was detected. CRP > 200 mg/L was associated with greater US-detected muscle loss on Day 5, while lactate > 2.5 mmol/L was associated with lower PhA.

Conclusions

Ultrasound reliably identified structural muscle wasting in critically ill patients, with no statistically significant effect of fluid balance detected in this cohort. Furthermore, ultrasound measurements were associated with inflammation-related muscle loss. In contrast, BIA was strongly influenced by hydration and perfusion status, limiting its ability to assess true muscle mass loss in the ICU setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceCritical CareFluid ShiftsWater-Electrolyte BalanceMuscle, SkeletalMuscular AtrophyHumansFemaleUltrasonographyMaleProspective StudiesCritical IllnessMiddle AgedC-Reactive ProteinAgedIntensive Care UnitsReproducibility of Results

Stichwörter der Autor:innen

bioelectrical impedance analysisfluid balanceintensive care unitmuscle ultrasoundmuscle wastingsystemic inflammation

Substanzen

C-Reactive Protein

Autor:innen und Institutionen

  • Clinic of Anaesthesiology and Intensive Care, Faculty of Medicine, Vilnius University, LT-01513 Vilnius, Lithuania.
  • Faculty of Medicine, Vilnius University, LT-01513 Vilnius, Lithuania.
  • Institute of Data Science and Digital Technologies, Faculty of Mathematics and Informatics, Vilnius University, LT-01513 Vilnius, Lithuania.

ORCID-Profile: Gintarė Šostakaitė, Martyna Jauniškytė, Erika Šalčiūtė-Šimėnė, Tomas Jovaiša, Tadas Žvirblis

Zitieren

APA

Šostakaitė, G., Jauniškytė, M., Budrys, D., Budrevičius, K., Šalčiūtė-Šimėnė, E., Svetikienė, M., Jovaiša, T., Žvirblis, T., Klimašauskas, A., & Šipylaitė, J. (2026). Fluid Shifts and Muscle Loss in Critical Care: Accuracy of Ultrasound Versus Bioelectrical Impedance Analysis. Nutrients, 18(12), 2019. https://doi.org/10.3390/nu18122019

Vancouver

Šostakaitė G, Jauniškytė M, Budrys D, Budrevičius K, Šalčiūtė-Šimėnė E, Svetikienė M, et al. Fluid Shifts and Muscle Loss in Critical Care: Accuracy of Ultrasound Versus Bioelectrical Impedance Analysis. Nutrients. 2026;18(12):2019. doi:10.3390/nu18122019

BibTeX
@article{ostakait2026,
  author = {Šostakaitė, Gintarė and Jauniškytė, Martyna and Budrys, Dominykas and Budrevičius, Kastytis and Šalčiūtė-Šimėnė, Erika and Svetikienė, Marija and Jovaiša, Tomas and Žvirblis, Tadas and Klimašauskas, Andrius and Šipylaitė, Jūratė},
  title = {Fluid Shifts and Muscle Loss in Critical Care: Accuracy of Ultrasound Versus Bioelectrical Impedance Analysis},
  journal = {Nutrients},
  year = {2026},
  volume = {18},
  number = {12},
  pages = {2019},
  doi = {10.3390/nu18122019}
}
Kostenlos starten →