Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity
Nutrients · 2025
DOI: 10.3390/nu17060971 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Nutrients, 2025. Verfasst von Alexandra Thajer und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, 109…. Hauptthemen laut MEDLINE: Absorptiometry, Photon, Electric Impedance, Pediatric Obesity, Body Composition. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund, Research Promotion Agency of Lower Austria (Gesellschaft für Forschungsförderung NÖ).
Abstract (Originalsprache)
Background
Body composition analysis is crucial in clinical practice, yet few methods are suitable for pediatric patients, and data on young children with obesity are limited.
Methods
This study measured body fat percentage (BFP), fat mass (FM), and fat-free mass (FFM) in 26 pediatric patients with obesity (BMI: 35.6±6.9 kg/m2), using two bioelectrical impedance analysis (BIA) devices (TANITA and BIACORPUS), and the results were compared to those of the gold-standard dual-energy X-ray absorptiometry (DXA). Additionally, air displacement plethysmography (BODPOD) was compared with DXA, and all methods were evaluated against each other.
Results
Significant differences were observed between all methods and parameters (p < 0.05). For example, Bland–Altman analysis for BFP identified differences between BIACORPUS and DXA (mean: −3.5%; 95% limits of agreement: −16.7% to 9.8%) and between TANITA and DXA (mean: −3.1%; 95% limits of agreement: −12.2% to 6.1%). These differences can be regarded as clinically relevant, especially when considering the 95% limits of agreement. Further, moderate differences between BODPOD and DXA were identified, which could be clinically relevant (mean: 2.1%; 95% limits of agreement: −4.2% to 8.5%).
Conclusions
TANITA was the most comparable BIA method to the gold standard, DXA. Therefore, TANITA is recommended for assessing body composition in young patients with obesity to monitor therapy progress in clinical settings. When using BODPOD as an alternative to DXA, caution is warranted since we found relevant differences between both methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pediatric Pulmonology, Allergology and Endocrinology, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, 1090 Vienna, Austria.
- Gender Medicine Unit, Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, 1090 Vienna, Austria.
- Division of Neuro- and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, 1090 Vienna, Austria.
- Department Health Sciences, FH Campus Wien-University of Applied Sciences, 1100 Vienna, Austria.
- Orthopaedic Hospital Speising, Laboratory of Gait and Movement Analysis, 1130 Vienna, Austria.
- Institute of Health Sciences, St. Pölten University of Applied Sciences, 3100 St. Pölten, Austria.
ORCID-Profile: Alexandra Thajer, Alexandra Kautzky-Willer, Sebastian Durstberger, Andreas Kranzl, Brian Horsak, Susanne Greber-Platzer
Förderung
- Austrian Science Fund
- Research Promotion Agency of Lower Austria (Gesellschaft für Forschungsförderung NÖ)
Zitieren
APA
Thajer, A., Vasek, M., Schneider, S., Kautzky-Willer, A., Kainberger, F., Durstberger, S., Kranzl, A., Horsak, B., & Greber-Platzer, S. (2025). Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity. Nutrients. https://doi.org/10.3390/nu17060971
Vancouver
Thajer A, Vasek M, Schneider S, Kautzky-Willer A, Kainberger F, Durstberger S, et al. Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity. Nutrients. 2025. doi:10.3390/nu17060971
BibTeX
@article{Thajer2025,
author = {Thajer, Alexandra and Vasek, Martin and Schneider, Sophie and Kautzky-Willer, Alexandra and Kainberger, Franz and Durstberger, Sebastian and Kranzl, Andreas and Horsak, Brian and Greber-Platzer, Susanne},
title = {Comparing Bioelectrical Impedance Analysis, Air Displacement Plethysmography, and Dual-Energy X-Ray Absorptiometry for Body Composition in Pediatric Obesity},
journal = {Nutrients},
year = {2025},
doi = {10.3390/nu17060971}
}
EUVIMED