Application of Filter Bank to Improve Fatigue Monitoring in Wearable EEG-Based Brain–Computer Interface
NeuroSci · 30.05.2026 · 7 (3) · 64
DOI: 10.3390/neurosci7030064 ↗Kurz gefasst
Fachartikel in der Zeitschrift NeuroSci, online erschienen am 30.05.2026. Verfasst von Timothy Jern Yu Tan und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Chemical Engineering and Biotechnology (CCEB), Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Fatigue monitoring and detection are crucial for improving efficiency and safety due to their influence on reducing cognitive and physical performance that may result in safety-related incidents. This paper proposes a filter bank-based approach that decomposes electroencephalography (EEG) signals into delta, theta, alpha, beta, and gamma sub-bands for feature extraction to enhance fatigue detection using a wearable EEG-based brain–computer interface (BCI). The study utilized a publicly available EEG dataset from 40 participants collected with a dry-EEG headband while performing two cognitive tasks: a Cognitive Vigilance Task (CVT) and a Multi-Modal Integration Task (MMIT). The data was previously investigated for stress detection on the MMIT. In this study, we investigate fatigue detection on the CVT. Subjects who were not fatigued post-CVT were iteratively removed. Two models were trained with five models to classify the fatigued state from the non-fatigued state, one using features extracted from a broadband filter approach and the other from the proposed filter bank approach. Leave-one-subject-out cross-validation yielded accuracies of 75.8% ± 10.4% (95% confidence interval) from the broadband filter approach, and 86.4% ± 8.3% (95% confidence interval) from the proposed filter bank approach, yielding an overall increase of 10.6%. These results demonstrate the potential of filter bank-based feature extraction for fatigue detection in wearable EEG-based BCI systems.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Chemistry, Chemical Engineering and Biotechnology (CCEB), Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
- Institute for Infocomm Research, Agency for Science, Technology and Research (A*STAR), 1 Fusionopolis Way, #21-01 Connexis (South Tower), Singapore 138632, Singapore.
- College of Computing and Data Science, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore.
- Home Team Science and Technology Agency (HTX), 1 Stars Avenue, #12-01, Singapore 138507, Singapore.
ORCID-Profile: Zhuo Zhang, Kai Keng Ang, Jennifer Ang
Zitieren
APA
Tan, T. J. Y., Zhang, Z., Ang, K. K., & Ang, J. (2026). Application of Filter Bank to Improve Fatigue Monitoring in Wearable EEG-Based Brain–Computer Interface. NeuroSci, 7(3), 64. https://doi.org/10.3390/neurosci7030064
Vancouver
Tan TJY, Zhang Z, Ang KK, Ang J. Application of Filter Bank to Improve Fatigue Monitoring in Wearable EEG-Based Brain–Computer Interface. NeuroSci. 2026;7(3):64. doi:10.3390/neurosci7030064
BibTeX
@article{Tan2026,
author = {Tan, Timothy Jern Yu and Zhang, Zhuo and Ang, Kai Keng and Ang, Jennifer},
title = {Application of Filter Bank to Improve Fatigue Monitoring in Wearable EEG-Based Brain–Computer Interface},
journal = {NeuroSci},
year = {2026},
volume = {7},
number = {3},
pages = {64},
doi = {10.3390/neurosci7030064}
}
EUVIMED