CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation
Neuroimaging · 23.11.2026 · 1 (4) · 19
DOI: 10.3390/neuroimaging1040019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neuroimaging, online erschienen am 23.11.2026. Verfasst von Chengpei Li und 8 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health including National Cancer Institute, Medtronic.
Abstract (Originalsprache)
Background/Objectives: In image-guided neurosurgery, brain shift degrades the accuracy of preoperative image-based navigation. Image updating addresses this by deforming preoperative images to match intraoperative anatomy using computational models driven by data such as intraoperative stereovision (iSV). However, these pipelines rely on user intervention, limiting wider adoption. In particular, cortex and resection cavity areas define boundary conditions, model tissue removal, and measure cortical shift, yet automatic segmentation remains challenging, and inaccuracies can limit image updating performance.
Methods
We present cortex- and resection-aware automated neurosurgical image segmentation (CRANIS), which extracts features from color and disparity images with Swin transformers and then fuses and decodes them via a holistically nested edge detection architecture to segment the cortex and resection cavity from iSV. Our dataset consisted of 231 cortex and 171 resection cavity cases (20% held-out test set and five-fold cross-validation on the remaining 80%). To demonstrate that CRANIS segmentations produce comparable image updating results to manual delineations, CRANIS was also integrated into the image updating pipelines in five representative test cases for initial exposure.
Results
CRANIS achieved median Dice similarity coefficient (DSC) values of 0.97 (cortex) and 0.85 (resection) with an average computational time of 1.67 s per image. Image updating with CRANIS achieved an average surface target registration error of 1.8 ± 1.1 mm, which is comparable to that of manual delineation (1.9 ± 1.0 mm). Even the worst-performing resection-stage case (DSC = 0.53) produced comparable results (1.8 ± 0.1 mm).
Conclusions
By eliminating manual segmentation, CRANIS supports future wider adoption of image updating in neuro-navigation.
Förderung
- National Institutes of Health including National Cancer Institute
- Medtronic
Zitieren
APA
Li, C., Warner, W. R., Biswas, B. A., Bhattacharya, I., Davis, S. C., Evans, L. T., Roberts, D. W., Paulsen, K. D., & Fan, X. (2026). CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation. Neuroimaging, 1(4), 19. https://doi.org/10.3390/neuroimaging1040019
Vancouver
Li C, Warner WR, Biswas BA, Bhattacharya I, Davis SC, Evans LT, et al. CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation. Neuroimaging. 2026;1(4):19. doi:10.3390/neuroimaging1040019
BibTeX
@article{Li2026,
author = {Li, Chengpei and Warner, William Ross and Biswas, Bashirul Azam and Bhattacharya, Indrani and Davis, Scott C. and Evans, Linton T. and Roberts, David W. and Paulsen, Keith D. and Fan, Xiaoyao},
title = {CRANIS: Cortex- and Resection-Aware Automated Neurosurgical Image Segmentation},
journal = {Neuroimaging},
year = {2026},
volume = {1},
number = {4},
pages = {19},
doi = {10.3390/neuroimaging1040019}
}