Manjila Chiari Protocol 2.0 (MaChiP 2.0) for Artificial Intelligence Incorporating Dynamic and Static Craniospinal Imaging in Evaluating Headaches with Chiari I Malformation—A Call to Action
Neuroimaging · 2026
DOI: 10.3390/neuroimaging1020008 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Neuroimaging, 2026. Verfasst von Sunil Manjila und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
MaChiP 1.0 used static magnetic resonance imaging (MRI) to identify coexistent idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) in Chiari I malformation (CM-I), improving etiologic characterization. This Protocol/Perspective paper presents MaChiP 2.0 as a testable, artificial intelligence (AI)-integrated imaging roadmap for acquired Chiari I malformation (CM-I), intended to support the differentiation between congenital and acquired tonsillar descent and to guide leak-localization imaging in suspected spontaneous intracranial hypotension (SIH). Building on the structural foundation of MaChiP 1.0, this framework outlines how dynamic craniospinal imaging tools, including phase-contrast magnetic resonance imaging (PC-MRI) and displacement encoding with stimulated echoes (DENSE), may be combined with conventional morphologic markers to refine imaging evaluation. It further describes the potential use of currently available artificial intelligence (AI) methods for segmentation, cerebrospinal fluid (CSF) flow quantification, and imaging biomarker assessment. Noninvasive magnetic resonance (MR)-based techniques are proposed as first-line approaches for leak detection, while digital subtraction myelography (DSM) and computed tomography myelography (CTM) remain the reference standards when initial imaging is inconclusive.
Zitieren
APA
Manjila, S., Ranjini, N. J., Rathore, S., Medani, K., Mani, S., Sideras, P., Kaimal, G., Siravuru, A., & Rayasam, K. (2026). Manjila Chiari Protocol 2.0 (MaChiP 2.0) for Artificial Intelligence Incorporating Dynamic and Static Craniospinal Imaging in Evaluating Headaches with Chiari I Malformation—A Call to Action. Neuroimaging. https://doi.org/10.3390/neuroimaging1020008
Vancouver
Manjila S, Ranjini NJ, Rathore S, Medani K, Mani S, Sideras P, et al. Manjila Chiari Protocol 2.0 (MaChiP 2.0) for Artificial Intelligence Incorporating Dynamic and Static Craniospinal Imaging in Evaluating Headaches with Chiari I Malformation—A Call to Action. Neuroimaging. 2026. doi:10.3390/neuroimaging1020008
BibTeX
@article{Manjila2026,
author = {Manjila, Sunil and Ranjini, Nived Jayaraj and Rathore, Saima and Medani, Khalid and Mani, Sudhan and Sideras, Panagiotis and Kaimal, Gayatri and Siravuru, Avinash and Rayasam, Karthik},
title = {Manjila Chiari Protocol 2.0 (MaChiP 2.0) for Artificial Intelligence Incorporating Dynamic and Static Craniospinal Imaging in Evaluating Headaches with Chiari I Malformation—A Call to Action},
journal = {Neuroimaging},
year = {2026},
doi = {10.3390/neuroimaging1020008}
}
EUVIMED