Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes

Elisabeta-Irina Geana iD, Corina Teodora Ciucure, Amalia Soare, Stanica Enache, Roxana Elena Ionete iD, Livia Alexandra Dinu iD

Nanomaterials · 28.05.2024 · 14 (11) · 948

DOI: 10.3390/nano14110948 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanomaterials, online erschienen am 28.05.2024. Verfasst von Elisabeta-Irina Geana und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Research and Development Institute for Cryogenics and Isotopic Technologies-ICSI Rm. Valcea, 240050 Râmnicu Vâlcea, Romania. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Research, Innovation and Digitization, UEFISCDI, Romanian Ministry of Research, Innovation and Digitization through NUCLEU Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study addresses the necessity to monitor the presence of glyphosate (Gly) in waters, highlighting the need for on-site detection of Gly by using electrochemical sensors in environmental and agricultural monitoring programs. Two approaches were employed: (1) modification with graphene decorated with gold nanoparticles (AuNPs-Gr) and dispersed in either dimethylformamide (DMF) or a solution containing Nafion and isopropanol (NAF), and (2) molecularly imprinted polymers (MIPs) based on polypyrrole (PPy) deposited on gold SPEs (AuSPE). Electrochemical characterization revealed that sensors made of AuNPs-Gr/SPCE exhibited enhanced conductivity, larger active area, and improved charge transfer kinetics compared to unmodified SPEs and SPEs modified with graphene alone. However, the indirect detection mechanism of Gly via complex formation with metallic cations in AuNPs-Gr-based sensors introduces complexities and compromises sensitivity and selectivity. In contrast, MIPPy/AuSPE sensors demonstrated superior performance, offering enhanced reliability and sensitivity for Gly analysis. The MIPPy/AuSPE sensor allowed the detection of Gly concentrations as low as 5 ng/L, with excellent selectivity and reproducibility. Moreover, testing in real surface water samples from the Olt River in Romania showed recovery rates ranging from 90% to 99%, highlighting the effectiveness of the detection method. Future perspectives include expanding the investigation to monitor Gly decomposition in aquatic environments over time, providing insights into the decomposition’s long-term effects on water quality and ecosystem health, and modifying regulatory measures and agricultural practices for mitigating its impact. This research contributes to the development of robust and reliable electrochemical sensors for on-site monitoring of Glyphosate in environmental and agricultural settings.

Schlagwörter

Stichwörter der Autor:innen

electrochemical sensorglyphosategold nanoparticlesgraphenemolecularly imprinted polymerpyrrole

Autor:innen und Institutionen

  • National Research and Development Institute for Cryogenics and Isotopic Technologies-ICSI Rm. Valcea, 240050 Râmnicu Vâlcea, Romania.
  • National Institute for Research and Development in Microtechnologies (IMT Bucharest), 077190 Voluntari, Romania.

ORCID-Profile: Elisabeta-Irina Geana, Roxana Elena Ionete, Livia Alexandra Dinu

Förderung

  • Ministry of Research, Innovation and Digitization
  • UEFISCDI
  • Romanian Ministry of Research, Innovation and Digitization through NUCLEU Program
  • Establishment and operationalization of a Competence Center for Soil Health and Food Safety-CeSoH
  • PNRR-National Recovery and Resilience Plan, C9 Support for the private sector, research, development and innovation, I5 Establishment and operationalization of…
  • CNCS—UEFISCDI
  • Romanian Ministry of Research Innovation and Digitalization
  • Institutional Performance—Projects to Finance Excellence in RDI

Zitieren

APA

Geana, E. I., Ciucure, C. T., Soare, A., Enache, S., Ionete, R. E., & Dinu, L. A. (2024). Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes. Nanomaterials, 14(11), 948. https://doi.org/10.3390/nano14110948

Vancouver

Geana EI, Ciucure CT, Soare A, Enache S, Ionete RE, Dinu LA. Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes. Nanomaterials. 2024;14(11):948. doi:10.3390/nano14110948

BibTeX
@article{Geana2024,
  author = {Geana, Elisabeta-Irina and Ciucure, Corina Teodora and Soare, Amalia and Enache, Stanica and Ionete, Roxana Elena and Dinu, Livia Alexandra},
  title = {Electrochemical Detection of Glyphosate in Surface Water Samples Based on Modified Screen-Printed Electrodes},
  journal = {Nanomaterials},
  year = {2024},
  volume = {14},
  number = {11},
  pages = {948},
  doi = {10.3390/nano14110948}
}