EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Terahertz Biosensor Engineering Based on Quasi-BIC Metasurface with Ultrasensitive Detection

Jun Peng iD, Xian Lin, Xiaona Yan, Xin Yan, Xiaofei Hu, Haiyun Yao, Lanju Liang, Guohong Ma iD

Nanomaterials · 04.05.2024 · 14 (9) · 799

DOI: 10.3390/nano14090799 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nanomaterials, online erschienen am 04.05.2024. Verfasst von Jun Peng und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Shanghai University, Shanghai 200444, China. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Special Funding of the Taishan Scholar Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Terahertz (THz) sensors have attracted great attention in the biological field due to their nondestructive and contact-free biochemical samples. Recently, the concept of a quasi-bound state in the continuum (QBIC) has gained significant attention in designing biosensors with ultrahigh sensitivity. QBIC-based metasurfaces (MSs) achieve excellent performance in various applications, including sensing, optical switching, and laser, providing a reliable platform for biomaterial sensors with terahertz radiation. In this study, a structure-engineered THz MS consisting of a “double C” array has been designed, in which an asymmetry parameter α is introduced into the structure by changing the length of one subunit; the Q-factor of the QBIC device can be optimized by engineering the asymmetry parameter α. Theoretical calculation with coupling equations can well reproduce the THz transmission spectra of the designed THz QBIC MS obtained from the numerical simulation. Experimentally, we adopt an MS with α = 0.44 for testing arginine molecules. The experimental results show that different concentrations of arginine molecules lead to significant transmission changes near QBIC resonant frequencies, and the amplitude change is shown to be 16 times higher than that of the classical dipole resonance. The direct limit of detection for arginine molecules on the QBIC MS reaches 0.36 ng/mL. This work provides a new way to realize rapid, accurate, and nondestructive sensing of trace molecules and has potential application in biomaterial detection.

Schlagwörter

Stichwörter der Autor:innen

metasurfacessensorsterahertz

Autor:innen und Institutionen

  • Department of Physics, Shanghai University, Shanghai 200444, China.
  • School of Opto-Electronic Engineering, Zaozhuang University, Zaozhuang 277160, China.

ORCID-Profile: Jun Peng, Guohong Ma

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province
  • Special Funding of the Taishan Scholar Project
  • Qingchuang Science and Technology Plan of Shandong Universities

Zitieren

APA

Peng, J., Lin, X., Yan, X., Yan, X., Hu, X., Yao, H., Liang, L., & Ma, G. (2024). Terahertz Biosensor Engineering Based on Quasi-BIC Metasurface with Ultrasensitive Detection. Nanomaterials, 14(9), 799. https://doi.org/10.3390/nano14090799

Vancouver

Peng J, Lin X, Yan X, Yan X, Hu X, Yao H, et al. Terahertz Biosensor Engineering Based on Quasi-BIC Metasurface with Ultrasensitive Detection. Nanomaterials. 2024;14(9):799. doi:10.3390/nano14090799

BibTeX
@article{Peng2024,
  author = {Peng, Jun and Lin, Xian and Yan, Xiaona and Yan, Xin and Hu, Xiaofei and Yao, Haiyun and Liang, Lanju and Ma, Guohong},
  title = {Terahertz Biosensor Engineering Based on Quasi-BIC Metasurface with Ultrasensitive Detection},
  journal = {Nanomaterials},
  year = {2024},
  volume = {14},
  number = {9},
  pages = {799},
  doi = {10.3390/nano14090799}
}