Effect of an Arm-Span-Adjusted Hand Position on Closed Kinetic Chain Upper Extremity Stability Test Performance and Muscle-Related Body Composition Associations
Muscles · 08.05.2026 · 5 (2) · 37
DOI: 10.3390/muscles5020037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscles, online erschienen am 08.05.2026. Verfasst von Filippos Christodoulou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Sciences, Physiotherapy Program, University of Nicosia, 46 Makedonitissas Avenue, 1700 Nicosia, Cyprus. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) is used to assess upper-extremity performance in a closed kinetic chain position. The standard hand placement of 36 inches may favor individuals with larger body dimensions.
Methods
Sixty-five healthy adults (44 males, 21 females; 18–33 years) performed the CKCUEST under two conditions: the standard position and a modified position with hand distance set at 50% of arm span. The mean number of touches, standard score, and power score were calculated for each condition. Reliability and the effects of sex and body composition were also examined.
Results
Performance was significantly better in the modified position for mean touches (24.4 ± 4.47 vs. 23.0 ± 4.62, p = 0.001), standard score (0.4 ± 0.07 vs. 0.3 ± 0.06, p = 0.001), and power (81.1 ± 18.29 vs. 77.1 ± 22.00, p = 0.001). Both conditions showed excellent reliability (ICC = 0.944–0.946). Females performed significantly fewer touches than males in the standard position (p = 0.001), whereas this difference was not significant in the modified position. Several anthropometric and body composition variables significantly predicted performance.
Conclusions
An arm-span-adjusted hand position improves CKCUEST performance and may provide a fairer assessment across individuals with different body dimensions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health Sciences, Physiotherapy Program, University of Nicosia, 46 Makedonitissas Avenue, 1700 Nicosia, Cyprus.
ORCID-Profile: Filippos Christodoulou, Irene-Chrysovalanto Themistocleous, Manos Stefanakis
Zitieren
APA
Christodoulou, F., Maniatis, P., Erotocritou, A., Hadjisavvas, S., Efstathiou, M. A., Themistocleous, I. C., & Stefanakis, M. (2026). Effect of an Arm-Span-Adjusted Hand Position on Closed Kinetic Chain Upper Extremity Stability Test Performance and Muscle-Related Body Composition Associations. Muscles, 5(2), 37. https://doi.org/10.3390/muscles5020037
Vancouver
Christodoulou F, Maniatis P, Erotocritou A, Hadjisavvas S, Efstathiou MA, Themistocleous IC, et al. Effect of an Arm-Span-Adjusted Hand Position on Closed Kinetic Chain Upper Extremity Stability Test Performance and Muscle-Related Body Composition Associations. Muscles. 2026;5(2):37. doi:10.3390/muscles5020037
BibTeX
@article{Christodoulou2026,
author = {Christodoulou, Filippos and Maniatis, Petros and Erotocritou, Andreas and Hadjisavvas, Stelios and Efstathiou, Michalis A and Themistocleous, Irene-Chrysovalanto and Stefanakis, Manos},
title = {Effect of an Arm-Span-Adjusted Hand Position on Closed Kinetic Chain Upper Extremity Stability Test Performance and Muscle-Related Body Composition Associations},
journal = {Muscles},
year = {2026},
volume = {5},
number = {2},
pages = {37},
doi = {10.3390/muscles5020037}
}
EUVIMED