EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intraday and Interday Reliability of Maximal and Explosive Handgrip Force–Time Metrics Using the Kinvent K-Grip Handheld Dynamometer

Ivan Curovic iD, Milan Markovic iD, Lazar Toskic, Jill Alexander, Damian J Harper

Muscles · 25.03.2026 · 5 (2) · 24

DOI: 10.3390/muscles5020024 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Muscles, online erschienen am 25.03.2026. Verfasst von Ivan Curovic und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Coaching and Performance, School of Health, Social Work and Sport, University of Lancashire, Preston PR1 2HE, UK. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

Handgrip strength (HGS) is a widely used indicator of neuromuscular function, with predictive values for health and performance outcomes. The aim of this study was to evaluate the intraday and interday reliability of maximal and explosive handgrip force–time metrics using the Kinvent K-Grip handheld dynamometer. (2)

Methods

Thirty-four participants performed three maximal voluntary isometric contractions per hand across two testing days. Force–time data were analysed for peak force (PF), mean force (MF), peak rate of force development (RFD), time-specific RFD, impulse, and forces at fixed time points. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), minimal detectable change (MDC), and coefficient of variation (CV%). (3)

Results

The device demonstrated excellent relative and absolute reliability for PF and MF across both days (ICC > 0.97; CV < 6%; MDC ≈ 5 kg). Later-phase explosive metrics (F250 and Imp200) showed good-to-excellent relative reliability (ICC = 0.88-0.99; CV = 4–14%), although with variable absolute reliability (MDC F250 ≈ 4–8 kg, MDC Imp200 ≈ 1 kg·s). For early-phase metrics, relative reliability was only moderate to good (ICC = 0.67–0.88) and characterised by a high degree of variability (CV = 15–22%). (4)

Conclusions

The K-Grip handheld dynamometer is a reliable tool for cross-sectional assessments and for tracking larger maximal strength and later-phase force improvements at fixed time points. Early-phase explosive metrics are less suitable for monitoring intervention effects due to high measurement error and fatigue sensitivity.

Schlagwörter

Stichwörter der Autor:innen

explosive forceimpulseneuromuscular functionrate of force developmentstrength assessment

Autor:innen und Institutionen

  • Institute of Coaching and Performance, School of Health, Social Work and Sport, University of Lancashire, Preston PR1 2HE, UK.
  • Faculty of Sport and Physical Education, University of Priština in Kosovska Mitrovica, 38218 Leposavić, Serbia.
  • Faculty of Sport, University ''Union-Nikola Tesla'', 11000 Belgrade, Serbia.

ORCID-Profile: Ivan Curovic, Milan Markovic

Zitieren

APA

Curovic, I., Markovic, M., Toskic, L., Alexander, J., & Harper, D. J. (2026). Intraday and Interday Reliability of Maximal and Explosive Handgrip Force–Time Metrics Using the Kinvent K-Grip Handheld Dynamometer. Muscles, 5(2), 24. https://doi.org/10.3390/muscles5020024

Vancouver

Curovic I, Markovic M, Toskic L, Alexander J, Harper DJ. Intraday and Interday Reliability of Maximal and Explosive Handgrip Force–Time Metrics Using the Kinvent K-Grip Handheld Dynamometer. Muscles. 2026;5(2):24. doi:10.3390/muscles5020024

BibTeX
@article{Curovic2026,
  author = {Curovic, Ivan and Markovic, Milan and Toskic, Lazar and Alexander, Jill and Harper, Damian J},
  title = {Intraday and Interday Reliability of Maximal and Explosive Handgrip Force–Time Metrics Using the Kinvent K-Grip Handheld Dynamometer},
  journal = {Muscles},
  year = {2026},
  volume = {5},
  number = {2},
  pages = {24},
  doi = {10.3390/muscles5020024}
}
Kostenlos starten →