EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of a Direct Cell-to-PCR Lysis Buffer Using Optimized Non-Ionic Detergents for RNA-Extraction-Free RT-qPCR

Mahmoud Zhra iD, Rawan Awni Alarawi iD, Shaimaa Abdelrahman Mohamed iD, Abdel Naser Daoud, Hana Fakhoury iD, Ahmad Aljada iD

Methods and Protocols · 31.07.2026 · 9 (4) · 114

DOI: 10.3390/mps9040114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Methods and Protocols, online erschienen am 31.07.2026. Verfasst von Mahmoud Zhra und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry and Molecular Medicine, College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Saudi NIH, Saudi National Institute of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Column-based RNA extraction is time-consuming, involves cumulative losses during transfer, wash, and elution steps, and has reduced recovery from sub-microliter inputs. These limitations restrict gene-expression analysis in small cell populations and low-titre pathogen detection in clinical specimens. We developed the Direct Cell-to-PCR Lysis Buffer, a defined non-ionic detergent formulation containing Tween 20 (0.3%), Triton X-100 (0.1%), and NP-40 (0.1%), for RNA-extraction-free one-step RT-qPCR. Lysates are added directly to reactions without pretreatment, heating, or column purification. Non-ionic detergents produced Ct values comparable to detergent-free controls, whereas SDS, Sarkosyl, and sodium deoxycholate abolished amplification. The method was benchmarked against the standard column-based PureLink RNA Mini Kit using SaOS-2 cells, MCF7 cells, peripheral blood mononuclear cells, and nasal and throat swabs. Direct lysates showed Ct offsets of 0.6 to 2.85 cycles compared with purified RNA, depending on sample type. Ubiquitin-C mRNA was detected down to a single-cell-equivalent input, and plasmid templates were detected to approximately 100 copies per reaction. The buffer was compatible with multiplex ScriptTaq COVID PCR, with unchanged RdRP, N, and RPP30 Ct values, and tolerated sodium azide up to 0.1%, supporting rapid direct RT-qPCR workflows.

Schlagwörter

Stichwörter der Autor:innen

RNA extraction-free workflowRT-qPCRSARS-CoV-2clinical swabsdirect lysislow-input gene expressionnon-ionic detergentssingle-cell detection

Autor:innen und Institutionen

  • Department of Biochemistry and Molecular Medicine, College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia.
  • College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia.
  • Department of Mechanical Engineering, College of Engineering, Alfaisal University, Riyadh 11533, Saudi Arabia.

ORCID-Profile: Mahmoud Zhra, Rawan Awni Alarawi, Shaimaa Abdelrahman Mohamed, Hana Fakhoury, Ahmad Aljada

Förderung

  • Saudi NIH
  • Saudi National Institute of Health

Zitieren

APA

Zhra, M., Alarawi, R. A., Mohamed, S. A., Daoud, A. N., Fakhoury, H., & Aljada, A. (2026). Development of a Direct Cell-to-PCR Lysis Buffer Using Optimized Non-Ionic Detergents for RNA-Extraction-Free RT-qPCR. Methods and Protocols, 9(4), 114. https://doi.org/10.3390/mps9040114

Vancouver

Zhra M, Alarawi RA, Mohamed SA, Daoud AN, Fakhoury H, Aljada A. Development of a Direct Cell-to-PCR Lysis Buffer Using Optimized Non-Ionic Detergents for RNA-Extraction-Free RT-qPCR. Methods and Protocols. 2026;9(4):114. doi:10.3390/mps9040114

BibTeX
@article{Zhra2026,
  author = {Zhra, Mahmoud and Alarawi, Rawan Awni and Mohamed, Shaimaa Abdelrahman and Daoud, Abdel Naser and Fakhoury, Hana and Aljada, Ahmad},
  title = {Development of a Direct Cell-to-PCR Lysis Buffer Using Optimized Non-Ionic Detergents for RNA-Extraction-Free RT-qPCR},
  journal = {Methods and Protocols},
  year = {2026},
  volume = {9},
  number = {4},
  pages = {114},
  doi = {10.3390/mps9040114}
}