Automated Peak Annotation in Time-of-Flight Secondary Ion Mass Spectrometry via a Physics-Informed Probabilistic Framework

Jiahua Chen, Yujie Cao, Xingyu Jiang, Chunpeng Wu, Qing Hao, Yun Hu, Jiahui Liu iD

Molecules · 07.07.2026 · 31 (13) · 2388

DOI: 10.3390/molecules31132388 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 07.07.2026. Verfasst von Jiahua Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Suzhou National Laboratory, Suzhou 215006, China. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Basic Research Program of Jiangsu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peak annotation in Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a persistent bottleneck that typically requires the manual assignment of chemical formulas to hundreds of fragment ion peaks per spectrum. This work describes a physics-informed probabilistic framework that automates this task by combining five chemically motivated constraints—Gaussian mass accuracy, element composition priors, isotope pattern matching, nitrogen rule parity, and graded valence bounds—into a multiplicative belief score. We evaluate the framework on 643 ground-truth peaks from 151 compounds spanning both positive and negative ion modes, and we explicitly distinguish two regimes. As a scoring task—when the correct formula is present in the candidate list—the framework attains 52.3% Top-1 and 76.4% Top-3 accuracy, a 4.9-fold improvement over mass-only scoring. In fully automated end-to-end deployment, where candidates are generated de novo, Top-1 accuracy is 26.3%; the limiting factor is candidate generation rather than scoring, as only 46.5% of ground-truth formulas are currently produced by the database and combinatorial generator. Leave-One-Compound-Out Cross-Validation (59 compounds, 525 peaks) yields 51.8% Top-1 accuracy with fixed domain-knowledge weights, confirming generalization stability. Ablation analysis identifies element composition priors as the dominant non-mass constraint (−27.7 percentage points when removed), followed by isotope matching (−10.3 pp) and the nitrogen rule (−5.3 pp). The framework requires no labeled training spectra—relying instead on physically motivated priors and curated fragment databases—provides interpretable per-constraint scores (which represent relative rankings rather than calibrated probabilities), and supports polarity-specific configurations, offering a practical computational foundation for automated ToF-SIMS spectrum interpretation.

Schlagwörter

Stichwörter der Autor:innen

ToF-SIMSbelief propagationfactor graphpeak annotationphysics-informed constraintsprobabilistic inferencesecondary ion mass spectrometry

Autor:innen und Institutionen

  • Suzhou National Laboratory, Suzhou 215006, China.

ORCID-Profile: Jiahui Liu

Förderung

  • Basic Research Program of Jiangsu

Zitieren

APA

Chen, J., Cao, Y., Jiang, X., Wu, C., Hao, Q., Hu, Y., & Liu, J. (2026). Automated Peak Annotation in Time-of-Flight Secondary Ion Mass Spectrometry via a Physics-Informed Probabilistic Framework. Molecules, 31(13), 2388. https://doi.org/10.3390/molecules31132388

Vancouver

Chen J, Cao Y, Jiang X, Wu C, Hao Q, Hu Y, et al. Automated Peak Annotation in Time-of-Flight Secondary Ion Mass Spectrometry via a Physics-Informed Probabilistic Framework. Molecules. 2026;31(13):2388. doi:10.3390/molecules31132388

BibTeX
@article{Chen2026,
  author = {Chen, Jiahua and Cao, Yujie and Jiang, Xingyu and Wu, Chunpeng and Hao, Qing and Hu, Yun and Liu, Jiahui},
  title = {Automated Peak Annotation in Time-of-Flight Secondary Ion Mass Spectrometry via a Physics-Informed Probabilistic Framework},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {13},
  pages = {2388},
  doi = {10.3390/molecules31132388}
}
Kostenlos starten →