Focused-Ion-Beam Artifacts and Evidence Reliability in Advanced Microscopy of Energy Materials
Molecules · 18.06.2026 · 31 (12) · 2148
DOI: 10.3390/molecules31122148 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 18.06.2026. Verfasst von Chen Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanics, Jinzhong University, Jinzhong 030606, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Doctoral Special Funding Project of Jinzhong University, Sichuan Science and Technology Program.
Abstract (Originalsprache)
Focused-ion-beam scanning electron microscopy (FIB-SEM) provides site-specific access to buried interfaces, particle interiors, porous electrode architectures, and localized degradation regions in energy materials. This capability is particularly valuable for rechargeable batteries, solid-state ion conductors, alkali-metal electrodes, and reactive solid–liquid interfaces, where the structures governing transport and failure are rarely exposed at a free surface. However, the preparation and imaging steps that reveal these regions may also alter them. Ion milling, environmental transfer, vacuum exposure, scanning electron microscopy (SEM), cryogenic handling, transmission electron microscopy (TEM), scanning transmission electron microscopy (STEM), energy-dispersive X-ray spectroscopy (EDS), electron energy-loss spectroscopy (EELS), and atom probe tomography (APT) can each modify local morphology, chemistry, or phase state. These effects are especially important when the intended evidence involves light elements, metastable phases, nanoscale coatings, reactive interphases, volatile species, or ion-conducting materials. This perspective develops a claim-specific framework for evaluating such results. Preparation- and imaging-induced changes are related to the material feature being interpreted and to the minimum control needed to distinguish the two origins. For porous electrodes, the relevant outputs include pore volume, connectivity, tortuosity, crack geometry, phase fraction, and active surface area. For reactive interfaces and solid electrolytes, the critical questions concern alkali-metal redistribution, surface amorphization, light-element contrast, implanted-species chemistry, and beam-induced phase formation. The discussion further compares conventional Ga-FIB, cryogenic FIB, Xe plasma FIB, low-energy Ar+ polishing, broad-ion-beam preparation, ultramicrotomy, and repeated particle-oriented FIB workflows. Reliable interpretation requires the preparation route, transfer conditions, imaging dose, analytical acquisition, and claim-specific controls to be reported together with the final microscopy result.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanics, Jinzhong University, Jinzhong 030606, China.
- College of Materials Science and Engineering, Sichuan University, Chengdu 610065, China.
- College of Materials Science and Engineering, National Engineering Research Center for Magnesium Alloys, Chongqing University, Chongqing 400044, China.
ORCID-Profile: Liangjuan Gao, Zhao Ding
Förderung
- Doctoral Special Funding Project of Jinzhong University
- Sichuan Science and Technology Program
Zitieren
APA
Chen, C., Gao, L., Jia, J., & Ding, Z. (2026). Focused-Ion-Beam Artifacts and Evidence Reliability in Advanced Microscopy of Energy Materials. Molecules, 31(12), 2148. https://doi.org/10.3390/molecules31122148
Vancouver
Chen C, Gao L, Jia J, Ding Z. Focused-Ion-Beam Artifacts and Evidence Reliability in Advanced Microscopy of Energy Materials. Molecules. 2026;31(12):2148. doi:10.3390/molecules31122148
BibTeX
@article{Chen2026,
author = {Chen, Chen and Gao, Liangjuan and Jia, Jiaqi and Ding, Zhao},
title = {Focused-Ion-Beam Artifacts and Evidence Reliability in Advanced Microscopy of Energy Materials},
journal = {Molecules},
year = {2026},
volume = {31},
number = {12},
pages = {2148},
doi = {10.3390/molecules31122148}
}
EUVIMED