EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Determination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry

Yaqi Liu iD, Yanyan Huo, Quan Han, Xiaohui Yang

Molecules · 09.06.2026 · 31 (12) · 2020

DOI: 10.3390/molecules31122020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, online erschienen am 09.06.2026. Verfasst von Yaqi Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical Engineering, Xi'an University, Xi'an 710065, China. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation of Shaanxi Province, Scientific Research Plan Projects of the Department of Education in Shaanxi Province, School-level Innovation and Entrepreneurship Project for College Students.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A new method has been established for determining trace amounts of platinum in water using ion liquid (IL)-dispersive liquid–liquid microextraction (DLLME) combined with graphite furnace atomic absorption spectroscopy (GFAAS). The method is based on the use of a self-prepared reagent, 5-(5-cyano-2-pyridineazo)-2,4-diaminotoluene (5-CN-PADAT), as a chelating agent, which reacts with Pt(IV) to form a hydrophobic chelate. The extraction solvent is 1-octyl-3-methylimidazolium hexafluorophosphate ([C8mim][PF6]), and ethyl acetate is used as the dispersive solvent. After the extraction is completed, the extraction phase formed by [C8mim][PF6] and ethyl acetate has a relatively low viscosity and can be directly used for the determination of GFAAS. A single-factor rotational method was employed to optimize conditions affecting DLLME extraction efficiency. The interactions among the factors affecting DLLME were analyzed using response surface optimization (RSM). Under optimal conditions, platinum concentrations exhibited good linearity within the range of 40–280 ng/mL, with a detection limit of 0.3 ng/mL. AGREEprep was used to discuss the ecological friendliness of the method, demonstrating its low cost, ease of operation, simple equipment requirements, and environmental friendliness. When applied to determining trace amounts of platinum in water samples, the results were satisfactory.

Schlagwörter

Stichwörter der Autor:innen

AGREEprepdispersive liquid–liquid microextractiongraphite furnace atomic absorption spectroscopyionic liquidplatinumresponse surface optimization

Autor:innen und Institutionen

  • School of Chemical Engineering, Xi'an University, Xi'an 710065, China.

ORCID-Profile: Yaqi Liu

Förderung

  • National Science Foundation of Shaanxi Province
  • Scientific Research Plan Projects of the Department of Education in Shaanxi Province
  • School-level Innovation and Entrepreneurship Project for College Students
  • Xi’an Key Laboratory of Food Safety Testing and Risk Assessment

Zitieren

APA

Liu, Y., Huo, Y., Han, Q., & Yang, X. (2026). Determination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry. Molecules, 31(12), 2020. https://doi.org/10.3390/molecules31122020

Vancouver

Liu Y, Huo Y, Han Q, Yang X. Determination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry. Molecules. 2026;31(12):2020. doi:10.3390/molecules31122020

BibTeX
@article{Liu2026,
  author = {Liu, Yaqi and Huo, Yanyan and Han, Quan and Yang, Xiaohui},
  title = {Determination of Trace Platinum in Water Samples by Ionic Liquid-Dispersive Liquid–Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry},
  journal = {Molecules},
  year = {2026},
  volume = {31},
  number = {12},
  pages = {2020},
  doi = {10.3390/molecules31122020}
}
Kostenlos starten →